BEA hereby declares that the IXIO-DT3 is in conformity with the basic requirements and the other relevant provisions of the directives
1999/5/EC and 2006/42/EC.
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 12 405836-001
Angleur, June 2013
Pierre Gardier, authorized representative and responsible for technical documentation
The complete declaration of conformity is available on our website: www.bea-pedestrian.be
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
TECHNICAL SPECIFICATIONS
Supply voltage:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Applicable directives:
Presence
Typical response time: < 200 ms (max. 500 ms)
Active infrared with background analysis
Spot: 5 cm x 5 cm (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
Solid-state-relay
(potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
Holdtime: 0.3 to 1 s
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms
EN 12978
EN ISO 13849-1:2008 PL «c» CAT. 2
(under the condition that the door control system
monitors the sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2
EN 16005:2012 Chapter 4.6.8;
DIN 18650-1:2010 Chapter 5.7.4
BS 7036-1:1996 Chapter 8.1
Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm
2
Solid-state-relay
(potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
Frequency output:
Pulsed signal (f= 100 Hz +/- 10%)
Current source output:
Galvanically isolated current source
No detection: current source ON
Open circuit voltage: 6.5 V
Output voltage available at 10 mA: 3 V min.
Typical load: up to 3 optocouplers in series
Detection: current source OFF
Open-circuit remained voltage: < 500 mV
EN 12978
EN ISO 13849-1:2008 PL «d» CAT. 2
EN 16005:2012 Chapter 4.6.8;
DIN 18650-1:2010 Chapter 5.7.4; AutSchR
BS 7036-1:1996 Chapter 7.3.2
(only applicable for frequency and current source
output)
Detection mode:
Technology:
Output:
Test input:
Norm conformity:
Specifications are subject to changes without prior notice.
All values measured in specific conditions.
12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10%
(to be operated from SELV compatible power supplies only)
< 2.5 W
2 m to 3.5 m
(local regulations may have an impact on the acceptable mounting height)
-25°C to +55°C; 0-95% relative humidity, non condensing
IP54
< 70 dB
20 years
R&TTE 1999/5/EC; MD 2006/42/EC; LVD 2006/95/EC; ROHS 2 2011/65/EU