Page 5 of 9
75.5751.11 IXIO-DT1 UL 20180305
3
4
+
+
+
2 s
4 s
OR
WID
TH
Part of the detection field can be masked to reduce its width.
The arrow position determines the width of the detection field.
INFRARED SAFETY FIELD
CLOSER
AWAY
If necessary, adjust the AIR-curtain
angle (from -7° to 4°, default 0°).
Activate the visible* spots to
verify the position of the AIR-
curtain.
ANGLE
TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES!
The size of the detection field varies according to the
mounting height and the settings of the sensor.
The full door width must be covered.
Always verify the actual detection field width by
walk-testing according to ANSI 156.10 guidance.
DOOR
max.
3 in**
Mounting
height
Detection
width
6’ 6"
7’
3
⁄
16
"
8’
3
⁄
16
"
9’
13
⁄
16
"
11’ 6"
6’ 6"
7’
3
⁄
16
"
8’
3
⁄
16
"
9’
13
⁄
16
"
11’ 6"
Additional
adjustments are
possible by LCD or
remote control
(see OVERVIEW OF
SETTINGS).
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than
8 in.
SET-UP 1 (QUICK)
reference picture
SET-UP 2 (ASSISTED)
test of full door cycle + reference picture
either hold the knob for 2 seconds, or use the
remote control buttons as specified
either hold the knob for 4 seconds, or use the
remote control buttons as specified
SET-UP
STEP OUT OF THE INFRARED FIELD!
OR
OR