BEA IXIO-DP1 User Manual Download Page 8

E

R

L

A

U

B

T

 

Z

E

R

T I

F I Z

I E R U N G

 

N

A

C

H

EN 1

600

5

E

N

A

B L E

S

 

A C C

O R

D

A

N

C

E

 

W

I

T

H

E

R

L

A

U

B

T

 

Z

E

R

T I

F I Z

I E R U N G

 

N

A

C

H

DIN 1

865

0

E

N

A

B L E

S

 

A C C

O R

D

A

N

C

E

 

W

I

T

H

BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | WWW.BEA-SENSORS.COM

©

B

EA 

 | 

O

ri

gi

na

l i

ns

tr

uc

ti

on

s

 |

 

4

2

.8

33

2 / V

2

 

- 11

.1

7

BEA hereby declares that the IXIO-DP1 is in conformity with the basic requirements and the other relevant provisions of the directives 
2014/53/EU,  and 2006/42/EC.
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 13089612
Angleur, September 2017 

Pierre Gardier, authorized representative and responsible for technical documentation

The complete declaration of conformity is available on our website

Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)

TECHNICAL SPECIFICATIONS

Supply voltage:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Applicable directives:

Presence

Typical response time: < 200 ms (max. 500 ms)

Active infrared with background analysis

Spot: 5 cm x 5 cm (typ)

Number of spots: max. 24 per curtain

Number of curtains: 2

-Input: 

Pulse polarity: positive or negative (adjustable)

Impedance:

   - Positive pulse: 2 K to ground

   - Negative pulse: 470 R to + sensor power supply

Pulse voltage: 6 V to 30 V

Pulse duration: 4 µs to 500 µs

Duty cycle: max. 50%

 

-Output:

Pulse polarity: negative

Level: 

   - Standby: Pulse from V to ground

   - Detection: V Supply

Topology: op-collector with 4.7 K to 3.3 V
Max. sink current: 25 mA with external 1 K to 24 V

EN 12978 
EN ISO 13849-1 PL «c» CAT. 2

(under the condition that the door control system 
monitors the sensor at least once per door cycle)

IEC 61496-1 ESPE Type 2
EN 16005 Chapter 4.6.8; 
DIN 18650-1 Chapter 5.7.4
BS 7036-1 Chapter 8.1

Motion

Min. detection speed: 5 cm/s

Microwave doppler radar

Transmitter frequency: 24.150 GHz

Transmitter radiated power: < 20 dBm EIRP

Transmitter power density: < 5 mW/cm

2

Solid-state-relay (potential and polarity free)

Max. contact current: 100 mA

Max. contact voltage: 42 V AC/DC

Detection mode:

Technology:

Output:

Norm conformity:

Specifications are subject to changes without prior notice.
All values measured in specific conditions and with a temperature of 25°C.

12 V - 30 V DC +/-10%  

(to be operated from SELV compatible power supplies only)

< 2.5 W
2 m to 3.5 m

 

(according to the applicable laws and regulations)

-25°C to +55°C; 0-95% relative humidity, non condensing
IP54
< 70 dB
20 years
RED 2014/53/EU; MD 2006/42/EC; ROHS 2 2011/65/EU

PL

EA

SE K

EE

P F

O

R F

U

R

TH

ER U

SE - D

ES

IG

N

ED F

O

R C

O

LO

U

R P

R

IN

TI

N

G

Summary of Contents for IXIO-DP1

Page 1: ...nob 9 IR curtain angle adjustment knob Opening safety sensor for automatic sliding doors User s Guide for product version 0400 and higher See product label for serial number ACCESSORIES BA Bracket accessory CA Ceiling accessory CDA Curved door accessory according to EN 16005 and DIN 18650 RA Rain accessory Download the BEA DECODER app for a quick overview of settings 9 V battery ENGLISH ...

Page 2: ...L FUNCTIONING FACTORY VALUE VS SAVED VALUE NAVIGATING IN MENUS Scroll menu items Push to enter the LCD menu new value is displayed more values are displayed current value is displayed displayed value saved value displayed value factory value Opening impulse Safety 6 6 Enter password if necessary Not during the first minute after power on of the sensor CHANGING A ZIP CODE Password X X X X ZIP code ...

Page 3: ... size 9 immunity 2 field size 9 immunity 2 field size 9 immunity 2 The size of the detection field varies according to the mounting height of the sensor from 15 to 45 default 30 from 15 to 15 default 0 ENGLISH IXIO DP1 INSTALLATION GUIDE GREEN BROWN YELLOW WHITE PINK GREY POWER SUPPLY POWER SUPPLY OPENING INPUT SAFETY OUTPUT SAFETY INPUT Output status when sensor is operational SENSOR Do not inver...

Page 4: ...utside door sensor should always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered OR STANDARD standard in and outdoor installations CRITICAL ENVIRONMENT critical installations due to surroundings or weather...

Page 5: ...se to each other should have a different frequency increased immunities 1 curtain increased immunities redirection motion and presence factory values for radar immunity IR immunity IR number and redirection small large bi uni uni AWAY low 0 5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s uni PRM bi auto uni auto PRM auto PRM for persons with reduced mobility AWAY unidirectional motion away from sensor aut...

Page 6: ...ened firmly Check position of cable and cover Increase the IR immunity filter to value 3 Select presetting 2 or 3 Select presetting 2 or 3 Increase radar immunity filter Change radar field angle Check if the sensor and door cover is fastened firmly Check position of cable and cover Change radar field size or angle Remove the objects if possible Launch an assisted setup and adjust the IR angle Repl...

Page 7: ...e for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor The warranty is inva...

Page 8: ... 5 cm typ Number of spots max 24 per curtain Number of curtains 2 Input Pulse polarity positive or negative adjustable Impedance Positive pulse 2 K to ground Negative pulse 470 R to sensor power supply Pulse voltage 6 V to 30 V Pulse duration 4 µs to 500 µs Duty cycle max 50 Output Pulse polarity negative Level Standby Pulse from V to ground Detection V Supply Topology op collector with 4 7 K to 3...

Reviews: