BEA Falcon Installation Manual Download Page 3

75.5835.04 FALCON FAMILY 20160301 

Page 3 of 4

XXS

XS

S

>

>

>

>

L

XL

XXL

0.5 s

1 s

2 s

3 s

4 s

5 s

6 s

7 s

8 s

9 s

3

4

5

6

1

2

P

A

(7)
(0)
(1)
(2)
(1)

POSSIBLE SETTINGS BY REMOTE CONTROL

FIELD SIZE

OUTPUT

CONFIGURATION

A = active output (relay active when detection)
P = passive output (relay active when no detection)

DETECTION MODE

uni

AWAY

FACTORY VALUES

RESETTING TO FACTORY VALUES:

Avoid proximity to neon 
lamps or moving objects. 

Do not cover the sensor.

DETECTION FILTER

HOLD-OPEN TIME

Avoid vibrations. 

Only open the sensor 
when the cable needs 
to be replaced.

Wall mounting

Ceiling mounting

Ceiling mounting

Bracket dimensions

Bracket dimensions

TO START OR END AN ADJUSTMENT SESSION, press and hold 

either

 push button until the LED flashes or 

stops flashing.

1

  FIELD SIZE

Parameter n°

2

  HOLD-OPEN TIME

3

  OUTPUT CONFIGURATION

4

  DETECTION MODE

5

  DETECTION FILTER

Value (factory values)

TO SCROLL THROUGH THE 
PARAMETERS, press 
the 

right

 push button.

TO CHANGE THE VALUE OF 
THE CHOSEN PARAMETER, 
press the 

left

 push button.

TO RESET TO FACTORY VALUES, press and hold 

both

 push buttons until both LEDs flash.

POSSIBLE SETTINGS BY PUSH BUTTONS

MOUNTING TIPS

DIMENSIONS (inches)

bi = two-way detection

uni = one-way detection towards sensor

uni AWAY = one-way detection away from sensor

bi

uni

Summary of Contents for Falcon

Page 1: ...ng height Degree of protection Temperature range Dimensions Tilt angles Materials Weight Cable length Norm conformity microwave doppler radar 24 150 GHz 20 dBm EIRP 5 mW cm motion FALCON 13 x 16 ft 16ft FALCON XL 13 x 6 5 ft 8 2ft FALCON WIDE 30 x 11 ft 21 ft typical at 30 and field size 9 2 in s 12V to 24V AC 10 12V to 24V DC 30 10 50 to 60 Hz 2 W relay free of potential change over contact 42V A...

Page 2: ...e push buttons All detection field dimensions were measured in optimal conditions and with field size value 9 CEILING WALL Choose the right detection filter for your application with the remote control or the push buttons Value recommendations according to angle and height Detection of all targets pedestrians and parallel traffic are detected 1 no specific filter 2 filter against disturbances reco...

Page 3: ...to be replaced Wall mounting Ceiling mounting Ceiling mounting Bracket dimensions Bracket dimensions TO START OR END AN ADJUSTMENT SESSION press and hold either push button until the LED flashes or stops flashing 1 FIELD SIZE Parameter n 2 HOLD OPEN TIME 3 OUTPUT CONFIGURATION 4 DETECTION MODE 5 DETECTION FILTER Value factory values TO SCROLL THROUGH THE PARAMETERS press the right push button TO C...

Page 4: ...ease the tilt angle Increase the detection filter value Reduce the field size Enter the right access code If you do not know the access code cut the power supply and restore it to access the sensor and change the access code or delete it Change the antenna angle Decrease the field size Increase the detection filter value The door opens for no apparent reason The sensor detects raindrops or vibrati...