BEA Falcon Installation Manual Download Page 1

75.5835.04 FALCON FAMILY 20160301 

Page 1 of 4

FALCON

1
2

5

6

4

3

Specifications are subject to changes without prior notice.
* Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer.
** Measured in optimal conditions

TECHNICAL SPECIFICATIONS

DESCRIPTION

ENGLISH

Activation sensor for automatic industrial doors*

1. 

push buttons

2. 

front face

3. 

radar antenna

4. 

angle indication

5. 

bracket

6. 

cable

Technology:
Transmitter frequency:  
Transmitter radiated power:
Transmitter power density:
Detection mode:
Detection zone:

Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output: 
   Max. contact voltage:
   Max. contact current:
   Max. switching power:
LED-signal:
Mounting height: 
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Materials:
Weight:
Cable length:
Norm conformity:

microwave doppler radar
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm²
motion
FALCON: 13 x 16 ft @ 16ft ; FALCON XL: 13 x 6.5 ft @ 8.2ft; 
FALCON WIDE: 30 x 11 ft @ 21 ft. (typical at 30° and field size 9)
2 in/s** 
12V to 24V AC ±10%; 12V to 24V DC +30% / -10%
50 to 60 Hz
< 2 W
relay (free of potential change-over contact)
42V AC/DC
1A (resistive)
30W (DC) / 60VA (AC)
red: detection state, parameter indication; green: value indication
FALCON: 11.5 - 23 ft; FALCON XL: 6.5 - 11.5 ft; FALCON WIDE: 11.5 - 21 ft
IP65
from -22 °F to + 140 °F
5 in (L) x 4 in (H) x 3.75 in (W)
0° to 180° vertical
ABS and polycarbonate
14 oz
33 ft
R&TTE 1999/5/EC; EMC 2004/108/EC

FALCON: for normal to high mounting (11.5 - 23 ft) 

FALCON XL: for low mounting (6.5 - 11.5 ft)

FALCON WIDE: for wide detection field

For more information, please visit www.devancocanada.com 
or call toll free at 855-931-3334

Summary of Contents for Falcon

Page 1: ...ng height Degree of protection Temperature range Dimensions Tilt angles Materials Weight Cable length Norm conformity microwave doppler radar 24 150 GHz 20 dBm EIRP 5 mW cm motion FALCON 13 x 16 ft 16ft FALCON XL 13 x 6 5 ft 8 2ft FALCON WIDE 30 x 11 ft 21 ft typical at 30 and field size 9 2 in s 12V to 24V AC 10 12V to 24V DC 30 10 50 to 60 Hz 2 W relay free of potential change over contact 42V A...

Page 2: ...e push buttons All detection field dimensions were measured in optimal conditions and with field size value 9 CEILING WALL Choose the right detection filter for your application with the remote control or the push buttons Value recommendations according to angle and height Detection of all targets pedestrians and parallel traffic are detected 1 no specific filter 2 filter against disturbances reco...

Page 3: ...to be replaced Wall mounting Ceiling mounting Ceiling mounting Bracket dimensions Bracket dimensions TO START OR END AN ADJUSTMENT SESSION press and hold either push button until the LED flashes or stops flashing 1 FIELD SIZE Parameter n 2 HOLD OPEN TIME 3 OUTPUT CONFIGURATION 4 DETECTION MODE 5 DETECTION FILTER Value factory values TO SCROLL THROUGH THE PARAMETERS press the right push button TO C...

Page 4: ...ease the tilt angle Increase the detection filter value Reduce the field size Enter the right access code If you do not know the access code cut the power supply and restore it to access the sensor and change the access code or delete it Change the antenna angle Decrease the field size Increase the detection filter value The door opens for no apparent reason The sensor detects raindrops or vibrati...

Reviews: