BEA Eagle5 User Manual Download Page 2

2/2 

 
 
 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Avoid vibrations!

 

  Do not cover the sensor! 

 

Avoid moving objects  

in proximity of the sensor! 

 

Avoid HF lamps or 

fluorescent lighting  

in proximity of the sensor! 

 

Avoid touching 

electronics! 

 
 

 
 
 

 
 

 
 
 

 

 

Technology  

: microwave and microprocessor 

Transmitter frequency    

: 24.175 GHz 

Transmitter radiated power 

: <20 dBm EIRP 

Transmitter power density 

: < 5mW/cm² 

Maximum mounting height   

: 3m  

Tilt angles 

: 0° to 90° vertical and -30° to + 30° lateral 

Detection field 

(mounting height=2.2m) 

: 4m (W) x 2m (D) 

Detection mode

 

: motion 

Minimum speed 

: 5 cm/s (measured in the sensor axis) 

Supply voltage 

: 12V to 24V AC/DC +30% / -10% 

Mains frequency 

: 50 to 60 Hz 

Power consumption 

: < 2W (VA) 

Output relay 

(free of potential change-over contact) 

Max. contact voltage 

Max. contact current 

Max. switching power 

 

: 42V AC- 60V DC 

: 1A (resistive) 

: 30W (DC) / 60VA (AC) 

Hold time 

: 0.5s 

Temperature range 

: -20°C to +55°C 

Degree of protection 

: IP54 

Norm Conformity 

: R&TTE 1999/5/EC; EMC 89/336/EEC 

Material 

: ABS 

Color of housing 

: black smoked, aluminium finish 

Dimensions 

: 120mm (W) x 80mm (H) x 50mm (D) 

Weight 

: 0.215kg 

Length of cable 

: 2.5m 

 

 
 
 

 

 
 

 

 

 

 

                   

    

 

 

 

 

 

 

 

 

 

EBA 

 

ECA

 

 

ERA 

 

Planar antenna for narrow detection field 

 
 

 

SYMPTOMS 

PROBABLE CAUSES 

CORRECTIVE ACTION 

The door will not open and no red LED 
lights up. 

The sensor power is off. 

Check the wiring and the power supply. 

The door opens and closes constantly. 

The sensor "sees" the door moving. 

Increase the tilt angle and/or reduce the sensitivity. 

 

When closing, the door creates 
vibrations picked up by the sensor. 

Make sure that the sensor is correctly fixed.  
Switch to unidirectional mode (dip switch 1: ON).  
Increase the immunity (dip switch 4: ON).  
Reduce the sensitivity. 

The door will not close. 
Red LED is OFF. 

ON-OFF switch at door control is in 
wrong position or faulty.  
Improper output configuration. 

Make sure that the ON-OFF switch for the door is in the ON or 
AUTOMATIC position. Check the output configuration setting 
on each sensor connected to the door operator. 

It rains and the sensor detects for no 
apparent reason. 

The sensor detects the motion of the 
rain drops. 

Use the ERA accessory. Switch to unidirectional mode and 
increase the immunity (dip switches 1&4: ON). 