BEA EAGLE X-MTF User Manual Download Page 5

5/8 

Note: 

    

All parameters or functions listed in the following tables are only accessible if the sensor is in adjustment session. The red LED flashes slowly. 

 

During an adjustment session each parameter may be checked or changed at any time in the following way :

 

PARAMETERS 

 OPERATIONS 

CHECK 
VALUES 

 

Press the key corresponding to the parameter to be checked and then press the 

CHECK VALUES 

key (15). 

The number of times the LED flashes corresponds to the value of the checked parameter. No LED flash corresponds to the value 0. 
Repeat this operation to check the value of the other parameters if required. 
Example: 

SENSITIVITY

 key (7) – 7 flashes of the LED: the radar sensitivity is set at the value 7. 

CHECK VALUES

 :   

 

 

    

PLUS 

 

Press the key corresponding to the sensitivity (7) or holdtime (6) parameter to be modified and then press the 

PLUS 

key (3) to increase the 

value by 1 unit.

 

PLUS

 : 

 

 

 

MINUS 

 

Press the key corresponding to the sensitivity (7) or holdtime (6) parameter to be modified and then press the 

MINUS 

key (5) to reduce the 

value by 1 unit.

 

MINUS

 :  

 

 

 

 

Note about LED signal: The red LED flashes quickly waiting for the value. Once this has been entered, it flashes slowly again.

 

PARAMETERS 

OPERATIONS 

DEFINITIONS - ADVICES 

SENSITIVITY 

 

Press the 

SENSITIVITY 

key (7). 

Use the 

NUMBER 

keys 

0-9 

(1) to enter the required sensitivity (or adjust this 

parameter using the 

PLUS 

(3) or 

MINUS 

(5) keys as explained above) 

SENSITIVITY :

   

 

  

 

 

To increase the 

sensitivity 

means to increase the sensor 

capabilities to detect small useful signals. Practically, to 
increase the sensitivity leads to increase the dimensions of the 
sensing field.  

HOLD TIME 

 

Press the 

HOLD TIME 

key (6). 

Use the 

NUMBER 

keys 

0-9

 (1) to enter the required hold time (0.5 s to 9 s) 

(or adjust this parameter using the 

PLUS 

(3) or 

MINUS 

(5) keys as explained 

above). 

HOLD TIME 

:  

 

 

 

 

The 

hold time

 allows extended output activation time after a 

motion detection has stopped. It is recommended to use this 
parameter instead of the operator’s one with the same function 
(interferences with the sensor). In X-MTF mode, the hold time 
defines the minimum required time during which no motion has 
to be "seen" by the sensor to release the detection. 

X-MTF 
SENSITIVITY 

 

Press the 

X-MTF

 

SENSITIVITY 

key (12). 

Use the 

NUMBER 

keys 

0-9 

(1) to enter the required sensitivity. 

0 = X-MTF OFF 
 
 

X-MTF SENSITIVITY :

   

   

 

 

The sensor switches to X-MTF mode after a motion detection 
occurs (if X-MTF-Sensitivity is set to a value higher than 0). 
The sensor remains in X-MTF mode as long as a motion (even 
very small movements) is ‘seen’ by the sensor in any direction. 
Increasing this parameter increases the ability of the sensor to 
detect very small useful signals. Note: a higher X-MTF 
sensitivity increases the detection zone! 

DETECTION 
MODE 

 

Press the 

DETECTION MODE 

key (8). 

Use the 

NUMBER 

keys 

1-5

 (1) to select the required mode : 

Key 1 

: Bidirectional mode 

Key 2

 : Unidirectional mode 

Key 3

 : Unidirectional mode with MTF-function 

Key 4

 : Unidirectional mode reverse 

Key 5

 : Unidirectional mode reverse with MTF- function 

DETECTION MODE : 

 

 

 

 

With the 

bidirectional mode

, the approaching and departing 

target is detected. With the 

unidirectional

 mode, only the 

approaching

 target is detected. With the 

unidirectional

 mode 

reverse

, only the 

departing

 target is detected. 

Using the 

MTF (Motion Tracking Feature)

 enables the sensor 

to automatically switch from the unidirectional mode to 
bidirectional mode as soon as a target is detected. This 
function is recommended for applications with elderly people 
or anyone approaching the door hesitantly. 

 

IMMUNITY 

 

Press the 

IMMUNITY 

key (9).

 

Use the 

NUMBER 

keys 

1-9 

(1) to select the 

required mode:

 

Key 1

:     Low immunity 

Key 2

:     Normal 

Key 3

:     Increased immunity 

IMMUNITY :

    

                                                      

   

 

 

To 

increase the immunity

 means to strengthen the 

resistance to external disturbances such as 

rain, vibrations

etc. 

MOUNTING 
HEIGHT 

  

Press the 

MOUNTING HEIGHT 

key (13),  

Use the 

NUMBER 

keys 

1-2 

(1) to select the required mounting height : 

Key 1 

: Standard mounting height 

Key

 

2

 : High mounting height 

MOUNTING HEIGHT

:  

    

   

 

 

The sensor presents an increased sensitivity scale in 

high 

mounting mode

. This setting is recommended when the 

detection on the field limits is erratic.  

Attention

: the high mounting mode can only be used in 

appropriate areas. 

OUTPUT 
CONFIGURA-
TION 

 

Press the 

OUTPUT CONFIGURATION

 key (17). 

Use the NUMBER keys 

1-2

 (1) to select the required output configuration : 

Key 1

 : Active mode 

Key 2

 : Passive mode 

OUTPUT CONFIGURATION

:  

   

 

 

 

Active 

Passive 

Detection 

 

 

No Detection 

 

 

 

DOOR 
CONTROL 

 

  

Press the 

DOOR CONTROL

 key (14),  

Use the NUMBER keys 

1-3

 (1) to select the required door control: 

Key 1

 : Automatic mode  

Key 2

 : Door permanently open 

Key 3

 : Door permanently closed 

DOOR CONTROL:

  

 

 

 

In ‘’door permanently open’’ mode, the sensor is continuously 
detecting. The red LED is continuously ON. 
In ‘’door permanently closed’’ mode, the sensor is in standby. 
It detects nothing anymore and the LED is continuously OFF. 

Summary of Contents for EAGLE X-MTF

Page 1: ... 0 215 kg Material ABS Color of housing anthracite gray aluminum finish or white Length of cable 2 5 m Manual adjustment Sensitivity by push buttons Orientation of sensing field mechanically Remote control adjustments Sensitivity Hold time X MTF Sensitivity Detection mode Immunity Mounting height Output configuration Door control Security 10 levels from 0 5s to 9s in 10 levels 9 levels uni bidirec...

Page 2: ...24V AC DC COM NO NC This device may be fixed on the ceiling as long as the spherical part of the sensor is facing in the direction opposite the door and as long as an angular position of around 70 is chosen for the antenna For the mounting on the upper part of the door operator profile use the EBA support For a mounting into the ceiling use the ECA embedding support For a better water tightness us...

Page 3: ...NED BY THE LATERAL ANGLE OF THE PLANAR ANTENNA The sensing fields correspond to the following adjustments Lateral angle of antenna 30 30 Mounting height 2 2 m D POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL ANGLE OF THE ANTENNA The sensing fields correspond to the following adjustments Mounting height 2 2 m Sensitivity 9 To obtain a sensing field as close to the door as possible set ...

Page 4: ... 1 The access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 During the first sensor adjustment or if the access code is reset to the 0000 value factory setting or during the first minute after the power on press only the UNLOCK key 4 no access code required UNLOCK with access code of 4 digits UNLOCK with access code of less than 4 digits UNLOCK without access cod...

Page 5: ...to X MTF mode after a motion detection occurs if X MTF Sensitivity is set to a value higher than 0 The sensor remains in X MTF mode as long as a motion even very small movements is seen by the sensor in any direction Increasing this parameter increases the ability of the sensor to detect very small useful signals Note a higher X MTF sensitivity increases the detection zone DETECTION MODE Press the...

Page 6: ...sor power is off The door control is set to level 3 Check the wiring and the power supply Set door control to automatic mode level 1 The sensor sees the door moving Increase the tilt angle and or reduce the sensitivity and or increase the immunity The door opens and closes constantly When closing the door creates vibrations picked up by the sensor Ensure that the sensor is correctly fixed Switch t...

Page 7: ...ck during the first minute after powering Press on unlock then on lock and introduce a new access code Batteries in the remote control are weak or installed improperly Check the batteries insertion Change the batteries The sensor does not respond to the remote control Remote control badly pointed Point the remote control towards the sensor TROUBLE SHOOTING ...

Page 8: ...ion of conformity and other technical documentation are available on our website or can be requested by phone or mail BEA S A LIEGE Science Park Allée des Noisetiers 5 B 4031 Angleur Tel 3243616565 Fax 3243612858 info bea be www bea be ...