BEA EAGLE X-MTF User Manual Download Page 1

1/8 

    

 

EAGLE 

EAGLE 

EAGLE 

EAGLE X

X

X

X----MTF

MTF

MTF

MTF

      

USER’S GUIDE

 

 

INDOOR UNIDIRECTIONAL MOTION SENSOR  

FOR QUASI-PRESENCE DETECTION OF PERSONS  

 
 
 

Technology 

microwave and 
microprocessor

 

Transmitter frequency  

24.175 GHz 

Transmitter radiated power 

< 20 dBm EIRP 

Transmitter power density 

< 5 mW/cm² 

Mounting height   

 

 

 

Standard 

from 1.8 m to 3 m 

 

High 

from 3 m to 4 m * 

Tilt angles 

0° to 90° vertical 
-30° to + 30° lateral 

Detection area   

(mounting height = 2.2m)

 

1.5m (W) x 2m (D) 

Detection mode

 

motion, quasi-presence 
detection of persons 

Minimum speed 

2 cm/s (measured in the 
sensor axis) 

Supply voltage 

12V to 24V AC ±10% 
12V to 24V DC +30% / -10% 

Mains frequency 

50 to 60 Hz 

Power consumption 

< 2W (VA) 

Output relay 

(free of potential change-over contact) 

 

Max. contact voltage 

42V AC - 60V DC 

 

Max. contact current 

1A (resistive) 

 

Max. switching power 

30W (DC) / 60VA (AC) 

 

Hold time 

0.5 s to 9 s (adjustable) 

Temperature range 

-20°C to +55°C 

Application 

indoor use only 

Degree of protection 

IP54

 

Norms and conformity 

EMC 2004/108/EC

 

Dimensions 

120 mm (W) x 80 mm (H) x 50 mm (D)

 

Weight 

0.215 kg

 

Material 

ABS

 

Color of housing 

anthracite gray, aluminum finish  
or white

 

Length of cable 

2.5 m

 

Manual adjustment 

   

 

Sensitivity (by push buttons) 

 

Orientation of sensing field (mechanically)

 

Remote control adjustments 

 

Sensitivity 

 

Hold time 

 

X-MTF Sensitivity 

 

Detection mode 

 

Immunity 

 

 

Mounting height 

 

Output configuration 

 

Door control 

 

Security

 





 




10 levels 
from 0.5s to 9s in 10 levels 
9 levels 
uni-/bidirectional, MTF, reverse mode 
low immunity, normal, increased 
immunity 
standard, high 
active/passive 
automatic, permanently open/closed 
1-4 digit access code

 

 

* only in appropriate areas

 

 

 

 

 

Terminal block 

Cable openings

 

Infrared receiver 

LED 

Push buttons 

Lateral antenna position 
adjustment 

Planar antenna 

Vertical antenna position 
adjustment 

 

 

 

 

 

 

 

 

 

 

 

The sensor must be firmly 
fastened to prevent from 
vibrating.

 

The sensor must not be 
placed directly behind a 
panel or any kind of 
material.

 

The sensor must not 
have any object likely to 
move or vibrate in its 
sensing field.

 

The sensor must not 
have any fluorescent 
lighting in its sensing 
field. 

To avoid damage by 
electrostatic discharges, 
do not touch any 
electronic part of the 
sensor. 

 

 
DESCRIPTION OF 
THE SENSOR  

 
INSTALLATION 
TIPS

  

 

INTERNAL VIEW 

HOUSING  

(INTERNAL VIEW)

 

 
TECHNICAL 
SPECIFICATION 

Summary of Contents for EAGLE X-MTF

Page 1: ... 0 215 kg Material ABS Color of housing anthracite gray aluminum finish or white Length of cable 2 5 m Manual adjustment Sensitivity by push buttons Orientation of sensing field mechanically Remote control adjustments Sensitivity Hold time X MTF Sensitivity Detection mode Immunity Mounting height Output configuration Door control Security 10 levels from 0 5s to 9s in 10 levels 9 levels uni bidirec...

Page 2: ...24V AC DC COM NO NC This device may be fixed on the ceiling as long as the spherical part of the sensor is facing in the direction opposite the door and as long as an angular position of around 70 is chosen for the antenna For the mounting on the upper part of the door operator profile use the EBA support For a mounting into the ceiling use the ECA embedding support For a better water tightness us...

Page 3: ...NED BY THE LATERAL ANGLE OF THE PLANAR ANTENNA The sensing fields correspond to the following adjustments Lateral angle of antenna 30 30 Mounting height 2 2 m D POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL ANGLE OF THE ANTENNA The sensing fields correspond to the following adjustments Mounting height 2 2 m Sensitivity 9 To obtain a sensing field as close to the door as possible set ...

Page 4: ... 1 The access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 During the first sensor adjustment or if the access code is reset to the 0000 value factory setting or during the first minute after the power on press only the UNLOCK key 4 no access code required UNLOCK with access code of 4 digits UNLOCK with access code of less than 4 digits UNLOCK without access cod...

Page 5: ...to X MTF mode after a motion detection occurs if X MTF Sensitivity is set to a value higher than 0 The sensor remains in X MTF mode as long as a motion even very small movements is seen by the sensor in any direction Increasing this parameter increases the ability of the sensor to detect very small useful signals Note a higher X MTF sensitivity increases the detection zone DETECTION MODE Press the...

Page 6: ...sor power is off The door control is set to level 3 Check the wiring and the power supply Set door control to automatic mode level 1 The sensor sees the door moving Increase the tilt angle and or reduce the sensitivity and or increase the immunity The door opens and closes constantly When closing the door creates vibrations picked up by the sensor Ensure that the sensor is correctly fixed Switch t...

Page 7: ...ck during the first minute after powering Press on unlock then on lock and introduce a new access code Batteries in the remote control are weak or installed improperly Check the batteries insertion Change the batteries The sensor does not respond to the remote control Remote control badly pointed Point the remote control towards the sensor TROUBLE SHOOTING ...

Page 8: ...ion of conformity and other technical documentation are available on our website or can be requested by phone or mail BEA S A LIEGE Science Park Allée des Noisetiers 5 B 4031 Angleur Tel 3243616565 Fax 3243612858 info bea be www bea be ...

Reviews: