TROUBLESHOOTING

The door remains 
closed. 
The LED is OFF.

The sensor power is off.

Check the wiring and the power supply.

The door does not 
react as expected.

The door opens 
and closes 
constantly.

The LED
flashes quickly
after unlocking.

The sensor does 
not respond to the 
remote control.

Improper output 
configuration on the sensor.

The sensor is disturbed 
by the door motion or 
vibrations caused by the 
door motion.

The sensor needs an access 
code to unlock.

Batteries in the remote 
control are weak or 
installed improperly.

The door opens for 
no apparent reason.

It rains and the sensor 
detects the motion of the 
rain drops.

Remote control badly 
pointed.

Change the output configuration setting on 
each sensor connected to the door operator.

Make sure the sensor is fixed properly.
Make sure the detection mode is unidirectional.
Increase the antenna angle.
Increase the immunity filter.
Reduce the field size.

Change the antenna angle.
Decrease the field size.
Increase the immunity filter.

Enter the right access code.
If you forgot the code, cut and restore the power 
supply to access the sensor without access code. 
Change or delete the access code.

Check and change the batteries if necessary.

Point the remote control towards the sensor.

Make sure the detection mode is unidirectional.
Increase the immunity filter.
Install the ORA (rain accessory).

In highly reflective 
environments, the sensor 
detects objects outside of its 
detection field.

ACCESS CODE

The access code (1 to 4 digits) is recommended to set sensors installed close to each other.

SAVING AN ACCESS CODE:

DELETING AN ACCESS CODE:

In airlock vestibules, 
the sensor detects the 
movement of 
the opposite door.

Change the antenna angle.
Change the antenna.
Increase the immunity filter.

The door control setting (F2) 
is set to value 3 (closed).

Change the door control setting (F2) to value 1 
(automatic).

Once you have saved an access code, you always need to enter this code to unlock the sensor.
If you forget the access code, 

cut and restore the power supply

. During 1 minute, you can access the sensor without 

introducing any access code.

Only for EC countries: According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE)

PL

EA

SE K

EE

P F

O

R F

U

R

TH

ER U

SE - D

ES

IG

N

ED F

O

R C

O

LO

U

R P

R

IN

TI

N

G

Summary of Contents for Eagle One HM

Page 1: ...eight Degree of protection Temperature range Dimensions Tilt angles Material Weight Cable lenght Conformity microwave and microprocessor 24 150 GHz 20 dBm EIRP 5 mW cm motion 5 cm s 12V to 24V AC 10 12V to 24V DC 30 10 50 to 60 Hz 2 W relay free of potential change over contact 42V AC DC 1A resistive 30W DC 60VA AC from 4 m to 5 m IP54 from 20 C to 55 C 120 mm L x 80 mm H x 50 mm W 0 to 90 vertica...

Page 2: ...icated Fix the sensor firmly Avoid proximity to neon lamps or moving objects Do not cover the sensor Avoid vibrations Do not touch electronical parts APPLICATIONS Connect the wires accordingly 1 BROWN POWER SUPPLY 2 GREEN POWER SUPPLY 3 WHITE COM 4 YELLOW NO 5 YELLOW NC Wall mounting above sliding or revolving door Ceiling mounting in front of door sliding revolving or swing doors Mounting on door...

Page 3: ...ntact bi uni uni PRM FACTORY VALUES low normal Adjust the lateral antenna angle Adjust the vertical antenna angle OR RESETTING TO FACTORY VALUES ANGLE uni AWAY PRM AWAY uni PRM one way detection also of people with reduced mobility uni AWAY one way detection away from sensor HOLD OPEN TIME MOUNTING HEIGHT DOOR CONTROL 0 5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s auto open closed open the sensor detec...

Page 4: ...detection mode is unidirectional Increase the antenna angle Increase the immunity filter Reduce the field size Change the antenna angle Decrease the field size Increase the immunity filter Enter the right access code If you forgot the code cut and restore the power supply to access the sensor without access code Change or delete the access code Check and change the batteries if necessary Point the...

Reviews: