![BEA CGS-KF112 Manual Download Page 4](http://html1.mh-extra.com/html/bea/cgs-kf112/cgs-kf112_manual_2715787004.webp)
BEA hereby declares that the equipment type
CGS-KF112 is in compliance with European Directives
2014/53/EU (RED)
,
2011/65/EU (RoHS).
The full text of the EU declaration of conformity is available on our website.
©
B
EA |
O
ri
gi
na
l i
ns
tr
uc
ti
on
s
| 6
9.
14
8
4 / V
3 - 2
02
2.
0
6
BEA
/ A-B Area, 3rd Floor, No.1 Building / No.5 Xinghai Road, BDA, Beijing / CHINA
T
+86 10 57761630 |
F
+86 10 62628775 |
E
W
asia.beasensors.com
Make sure the sensor
installed firmly.
Avoid extreme vibrations.
Do not place the metallic
object in front of sensor,
or it will impact the detec-
tion effects.
Avoid proximity to neon
lamps or moving
objects.
TIPS
TROUBLE SHOOTING
For EU countries: This product should be disposed of separately from unsorted municipal waste.
The escalator controller
unit and the escalator
cover profile must be
correctly earthed.
The escalator is not activated
as supposed to be.
The LED is OFF.
The sensor power is off.
Check the wiring and the power supply.
The escalator is activated/
deactivated improperly.
The installation position, the
tilt angle or the sensitivity is
improper.
1
2
3
4
Make sure the sensor is fixed properly.
Adjust the tilt angle.
Adjust the sensitivity.
Adjust the immunity level.
The escalator keeps
running even when
nobody steps in.
The LED flashes irregular or
lights up permanently.
Output mode error.
Adjust to the Pulse mode.
Output configuration error.
Set a correct output configuration.
Sensitivity sets too large.
Set the appropriate sensitivity.
The power supply is not
properly grounded.
1
2
Increase the immunity level.
Make sure the power supply is properly grounded.
The escalator cannot enter
energy saving mode.
The LED is not working.
Output configuration error.
Set a correct output configuration.
BEA SA
| LIEGE Science Park | Allée des Noisetiers, 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | www.beasensors.com
Note: Inappropriate installation angle may cause wrong detection or unregular detection field.
Avoid putting complex
design cover in front of the