BEA 1SAFE User Manual Download Page 2

1

4

2

5

6

3

7

8

8

MOUNTING TEMPLA

TE

110

50

30

1

2

+4

0

-4

2/4

GREEN

OR

RED

Use the mounting template to cut 
out the opening for the sensor.

Unclips the front face by inserting 
a screwdriver as shown.

Push the push button shortly 
to launch an automatic setup.
The LED will flash RED-GREEN.

When the LED turns OFF the 
sensor is correctly installed. 
Fasten the front face and test the 
good functioning of the sensor.

If the LED continues flashing, 
you have to adjust the sensor 
further (see SETUP next page).

Connect the cable and insert 
the sensor into the opening.

After inserting the sensor, fix 
the 2 screws firmly.

The sensor can also be installed on the surface by using the surface 
mount accessory (sold seperately).

Adapt the angle of the sensor.

 INSTALLATION

OFF

RED-GREEN

NORMALLY OPEN

ACTIVE LOGIC

YELLOW-BLACK

NO POWER

NO DETECTION

DETECTION

NORMALLY CLOSED

PASSIVE LOGIC

YELLOW-WHITE

BROWN

Power supply
12-24V AC/DC

COM
NC
NO

Monitoring

GREEN

YELLOW

WHITE

RED

BLACK

BLUE