RAIN MODE
SNOW MODE -
STANDARD
WIZARD SMR
PROGRAMMING
GUIDE – Cont.
RAIN MODE:
1. The Rain Mode is designed to minimize the effect of heavy rain on the Wizard’s auto-learn
requirements. Rain Mode will be enabled after the Wizard goes through two auto-learn cycles within
no more than 6 detection cycles of the sensor between these 2 auto-learn cycles. During Rain Mode,
auto-learn time will remain the same. However, the second infrared curtain will change from IR
presence detection to IR motion detection. This is done to help eliminate unwanted detection of
heavy rain, as well as it’s effects on the ground. The only required setting on the Wizard SMR to
enable Rain Mode is IR Sensitivity, which must be set to a value of 2 (normal). This mode will
automatically expire upon a power reset, or upon expiration of one hour. This mode could be
launched again under the same conditions.
STANDARD SNOW MODE:
The Snow Mode is designed to minimize the effect of heavy snow on the Wizard’s auto-learn requirements.
Snow Mode may only be enabled by performing the following:
1. Using the BEA remote control, Unlock the Wizard as described in the programming guide.
+ unlock code, if necessary.
2.
Set Infrared Sensitivity to LOW (1).
+ 1 = Low Sensitivity
3.
Set Auto-Learn Time to 30 seconds (0).
+ 0 = 30 second learn-time
4.
Lock The Sensor when complete +
5. After the above changes have been made, the Wizard will go into the Standard Snow Mode after it
goes through 2 auto-learn cycles within no more than 6 detection cycles of the sensor between these
2 auto-learn cycles.
6.
While in Standard Snow Mode, the auto-learn time will change from 30 seconds to 10 seconds.
This mode will automatically expire upon a power reset, or upon expiration of one hour, as long as
the settings (as outlined above) are in effect. This mode could be launched again under the same
conditions.
DOOR CONTROL
FUNCTION
The Door Control function enables the User
to select a mode of door operation.
1 = Door permanently open.
2 = Door permanently closed – no
detection
3 = Door in automatic mode –
Wizard, upon detection, opens door.
After pressing the DOOR CONTROL
FUNCTION key, the red LED flashes
quickly. After pressing a number
button, the red LED flashes slowly.
3
IR CURTAIN
The IR Curtain function allows the User to
toggle the second IR curtain (farthest from
the door) on & off. When the curtain is off, it
operates in a motion sensing mode.
1 = 1 IR curtain (inner) ON.
2 = Both IR curtains (inner &
outer) ON.
2
After pressing the IR CURTAIN
FUNCTION key, the red LED flashes
quickly. After pressing a number
button, the red LED flashes slowly.
IMPORTANT NOTE:
When changing the values of the above parameters to go from one mode to another, one should
force a set-up by remote control, push buttons, or by a power-off / on sequence.