BEA 10WIZARDC User Manual Download Page 1

75.5101 V1 Sep. 2003 [Rev. 9/22/2003]

 

 

                

 

Page 1 of 16 

COMBINED 
SAFETY & 
ACTIVATION 
SENSOR

 

TECHNICAL 
SPECIFICATIONS

 

USERS GUIDE

  

WIZARD-C 

COMBINED ACTIVATION & SAFETY SENSOR 

PRELIMINARY 

 

 

The Wizard-C  (PN:10WIZARDC) combines k-band microwave and focused active infrared technology to provide superior 
activation and safety for an automatic sliding door system. For activation, the unit provides digitally processed and sophisticated 
motion tracking technology for unidirectional sensing when energy conservation is critical. For safety, the unit emits 2 rows of 24 
beams of focused presence technology that provides extraordinary safety. The active infrared remains active even when the door 
is closing. Serial numbers 52000 and greater provide the added ability for an “ALL RELAY” output, making it compatible with older 
non-microprocessed control boxes. 
 

 
 
 
 

DESCRIPTION

 

SPECIFICATION 

Supply voltage 

12 to 24  VAC / VDC: -5%  to +10% 

Power frequency  

50 / 60 Hz 

Power consumption  

 < 3 W 

Mounting height  
        

 Standard  

 

        

  High 

 
5’9” to 8’2” 
8’2” to 13” 

SMR data input 

 10 to 30 V DC 

Delay of the output activation after stimulation  

 transistor : < 1ms 

3-color LED 

 RED :        presence detection 

 GREEN  :  motion detection 

 ORANGE :monitoring process 

Temperature range 

-30°F  to  +131°F 

Degree of protection 

NEMA 3S / (IP54) 

Product conformity 

R&TTE 1999/5/EC & EMC 89/336/EEC  
BZT Germany, TÜV 

Dimensions 

10.4 " x 2.2 " x 1.9 " 

Weight 

.55 lbs / 250 g 

Housing material 

ABS & LURAN S  

Color of Housing 

Anthracite gray (standard), aluminum or white finish 

Cable length 

8’ of six-conductor cable 

 
 

 

MOTION SENSOR 

PRESENCE SENSOR 

Technology Microwave 

and 

microprocessor 

Transmitter frequency :24.125 GHz 
Transmitter radiated power : <20 dBm EIRP  
Transmitter power density : < 5 mW/cm² 

Focused active infrared and  
Self-monitored microprocessor 
Spot diameter (standard) : 4” max 
Number of spots : 24 or 12 spots by 
curtain 
Number of curtains : 2 

Detection field (standard) 
      

 Wide field  

      

 Narrow field 

 
13’0” W x 6’6” D 
6’6” W x 8’2” D 

 
6’6” W x 13.75” D 
3’3” W x 13.75” D 

Detection mode 

Minimum detection speed  
2 inches / sec. (measured in the sensor axis) 

Response time : < 128ms 
 

Angle :  

from  15°  to  50°  in elevation (adjustable) 

from - 4°   to   + 4°   (adjustable) 

Output specification  

Relay (free of potential change-over contact) : 

 Max contact voltage : 42V AC/DC 

 Max contact current : 1A (resistive) 

 Max switching power : 30W (DC) / 60VA (AC) 

Transistor (optocoupled transistor) 

 Max output current : 100 mA 

 Max switching power : 48 V DC 

 

Output hold-time 

 0.5s to 9s  (adjustable) 

 1s  (fixed) 

Manual adjustment  

 orientation of sensing field  (mechanically)  

 shape of the sensing field (choice of antenna) 

 multiple functions (using push buttons). 

 

 orientation of sensing field   

 shape of the sensing field (choice of 

front lens) 

 multiple functions (by push buttons). 

Remote control adjustments  

 Sensitivity. 

 Hold time. 

 Detection mode.  

 Immunity 

 Output configuration. 

 Sensitivity. 

 Auto-learn time 

 Monitoring mode 

 Number of Curtains  

 Relay / Transistor configuration 

 Rain Mode 

 Snow Mode 

 
 
 

 

We open up New Horizons

OBSOLETE

Summary of Contents for 10WIZARDC

Page 1: ...250 g Housing material ABS LURAN S Color of Housing Anthracite gray standard aluminum or white finish Cable length 8 of six conductor cable MOTION SENSOR PRESENCE SENSOR Technology Microwave and micro...

Page 2: ...ry for for all neagtive IR angles 3 Insert mounting screws about halfway in F shown on next page and install the Wizard onto the screws When in place tighten screws to secure to header Leave cover off...

Page 3: ...Page 8 Wizards below SN 52000 will still require a 10IFBWIZARD Other Wiring Notes 1 When connecting to a microprocessed control box the Motion output and presence output wires may be connected to sepa...

Page 4: ...tern being drawn back towards the door where as the 45 will place the pattern farther away Be certain to walk test detection field and insure compliance with current applicable ANSI standards 1 Insert...

Page 5: ...bring the pattern nearer or farther from the face of the door by adjusting the tilt angle from 4 to 4 At the standard mounting height one complete clockwise turn of the adjustment screw will move the...

Page 6: ...ng of 0 7 Default sensitivity value When all parameters have been set press the LOCK key once If you wish to enter a new access code use the 0 9 number keys and enter the new 4 digit code within 20 se...

Page 7: ...y the red LED flashes quickly After pressing a number button the red LED flashes slowly IMMUNITY motion Immunity reduces the influence of unwanted disturbances within the field of motion detection wit...

Page 8: ...conds 0 0 30 second learn time 4 Lock The Sensor when complete 5 After the above changes have been made the Wizard will go into the Standard Snow Mode after it goes through 2 auto learn cycles within...

Page 9: ...ay be accomplished by the use of two Wizard mounted programming buttons The procedures below indicate how to program using these buttons The two set buttons are located at the right side of the Wizard...

Page 10: ...y returns to standard mode if neither button has been pressed for one minute STEP 2 With all wiring in place apply power to door control and 12 to 24 VAC VDC 5 to 10 to Wizard Once powered observe LED...

Page 11: ...ontrol or motor Refer to manufacturer s manual for further troubleshooting If door closes with sensor inputs removed fault exists with sensors or related wiring 1 On Off switch at door control in wron...

Page 12: ...will not unlock when access code is entered 1 Improper code being entered 1 Reset code to the default value of 0000 by performing one of the following a Press the 2 buttons on the Wizard simultaneousl...

Page 13: ...B 3 of the interface PH 412 249 4100 FAX 412 249 4101 B E A Inc 100 Enterprise Drive Pittsburgh PA 15275 REV 1 OF 1 NONE SIZE CAGE CODE DWG NO FILE OF GDM 20 MAR 2002 GDM A STANLEY DURAGLIDE WITH WIZA...

Page 14: ...ZARD BROWN BLUE BLACK RED WHITE BROWN BLUE BLACK RED GREEN Reset 0 VDC Part open Exit Off 0 VDC Stop Impulse Pres Impulse 1 C Switch 0 v Pres Impulse 2 18 VDC 0 VDC Outer Impulse Inner Impulse 18 VDC...

Page 15: ...MPULSE 24 VDC MONITORED SAFETY ONLY PHOTOCELL BESAM UNISLIDE SLIDING DOOR WITH WIZARD SYSTEM SIZE SHEET SCALE A PH 412 249 4100 FAX 412 249 4101 B E A Inc 100 Enterprise Drive Pittsburgh PA 15275 DATE...

Page 16: ...ITCH PINS 5 6 7 LOOK SEE COM LINE PIN 8 LOOK SEE OUTPUT PINS 17 18 96010 900 QUANTUM SLIDE CONTROL BOX ACCESSORIES 24 VDC PIN 1 PIN 2 ACCESSORIES 24 VAC PINS 3 4 4 PIN 5 PIN EARTH GROUND NEUTRAL MAIN...