C/L
NOTE: The product should only be powered by a UL listed power supply.
NOTE: If power switch is not wired between DC source voltage and magnet,
it will take a longer time to de-energize the magnet simulating residual magnetism.
1.
12 VDC INPUT
A. Required power 0.5A (Max).
B. Connect ground (-) lead from a 12 VDC power source to Terminal 2.
C. Connect positive (+) lead from a 12 VDC power source to Terminal 1.
D. Check jumper for 12 VDC operation.
2.
24 VDC INPUT
A. Required power 0.25A (Max).
B. Connect ground (-) lead from a 24 VDC power source to Terminal 2.
C. Connect positive (+) lead from a 24 VDC power source to Terminal 1.
D. Check jumper for 24 VDC operation.
3.
CONTACTS
1. Relay dry contacts are rated 1A at 24 VDC for safe operation, DO NOT exceed this
rating.
2. If a NO switch is required, connect the wires from the system to Terminal 4 & Terminal 3.
3. If a NC switch is required, connect the wires from the system to Terminal 4 & Terminal 5.
Page 2 of 2
75.5366.00 20080821
5 Installation - Electrical
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please
contact BEA Inc. If you must wait for the following workday to contact BEA, leave the door inoperable until satisfactory
repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.
The following numbers can be called 24/7. For more information, visit
www.beasensors.com
.
6 Company Contact
US and Canada:
Canada:
Northeast:
1-866-249-7937
1-866-836-1863
1-866-836-1863
Southeast:
Midwest:
West:
1-800-407-4545
1-888-308-8843
1-888-419-2564
4 Installation - Mechanical (Cont’d)
TYPICAL INSTALLATION
NOTE: DO NOT over-tighten the armature plate. The rubber washer is
designed to allow the armature plate to automatically adjust position
for best mating position between the lock and armature plate.
1 2 3 4 5
+ - NO C NC
+ -
12VDC
24VDC
Switch or solid
state switching
device
Switch or solid
state switching
device
AC
110V
or
220V
AC
110V
or
220V
DC
12V
or
24V
DC
12V
or
24V
+
-
+
-
CORRECT
INCORRECT
LOCK STATUS SWITCH (SPDT)
POWER
SUPPLY
+ -
POWER
SELECTOR
JUMPER
LED
MAG BOND SENSOR
MAGNET
TIMER (0-90 SEC)
DOOR FRAME
ARMATURE PLATE
MAGNET
ANGLE
BRACKET
MOUNTING
PLATE
MOUNTING
PLATE
STRINGER
HOLE FOR
GUIDE PIN
HOLE FOR NUT
RUBBER WASHER
STEEL WASHER
ARMATURE PLATE
SCREW M8 (35MM)
GUIDE PIN
DOOR
NUT
SPACER
WASHER
ARMATURE
PLATE
DOOR
NUT
DOOR FRAME
DOOR FRAME
DOOR
ARMATURE PLATE
ARMATURE PLATE
MAGNET
MAGNET
DOOR
DOOR
MOUNTING
PLATE