background image

C/L

NOTE:  The product should only be powered by a UL listed power supply.

NOTE:  If power switch is not wired between DC source voltage and magnet,
             it will take a longer time to de-energize the magnet simulating residual magnetism.

1.

12 VDC INPUT

  

A.   Required power 0.5A (Max).

B.   Connect ground (-) lead from a 12 VDC power source to Terminal 2.

C.   Connect positive (+) lead from a 12 VDC power source to Terminal 1.

D.   Check jumper for 12 VDC operation.

2.

24 VDC INPUT

A.   Required power 0.25A (Max).

B.   Connect ground (-) lead from a 24 VDC power source to Terminal 2.

C.   Connect positive (+) lead from a 24 VDC power source to Terminal 1.

D.   Check jumper for 24 VDC operation.

3.

CONTACTS

1.   Relay dry contacts are rated 1A at 24 VDC for safe operation, DO NOT exceed this 

rating.

2.   If a NO switch is required, connect the wires from the system to Terminal 4 & Terminal 3.

3.   If a NC switch is required, connect the wires from the system to Terminal 4 & Terminal 5.

Page 2 of 2 

 

 

 

 

 

 

 

 

 

75.5366.00   20080821

5   Installation - Electrical

Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please 
contact BEA Inc.  If you must wait for the following workday to contact BEA, leave the door inoperable until satisfactory 

repairs can be made.  Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.

The following numbers can be called 24/7.  For more information, visit 

www.beasensors.com

.

6   Company Contact

US and Canada:

Canada:

Northeast:

1-866-249-7937

1-866-836-1863

1-866-836-1863

Southeast:

Midwest:

West:

1-800-407-4545

1-888-308-8843

1-888-419-2564

4   Installation - Mechanical (Cont’d)

 

TYPICAL INSTALLATION

NOTE:  DO NOT over-tighten the armature plate.  The rubber washer is 

designed to allow the armature plate to automatically adjust position 
for best mating position between the lock and armature plate.

1   2   3   4   5

+    -  NO  C  NC

+     -

  12VDC
  24VDC

Switch or solid

state switching

device

Switch or solid

state switching

device

AC

110V

           or

220V

AC

110V

           or

220V

DC

12V

        or

24V

DC

12V

        or

24V

+

-

+

-

CORRECT

INCORRECT

LOCK STATUS SWITCH (SPDT)

POWER 
SUPPLY  
     +    -

POWER

SELECTOR

JUMPER

LED
MAG BOND SENSOR
MAGNET

TIMER (0-90 SEC)

DOOR FRAME

ARMATURE PLATE

MAGNET

ANGLE
BRACKET

MOUNTING
PLATE

MOUNTING
PLATE

STRINGER

HOLE FOR
GUIDE PIN

HOLE FOR NUT

RUBBER WASHER

STEEL WASHER

ARMATURE PLATE

SCREW M8 (35MM)

GUIDE PIN

DOOR

NUT

SPACER

WASHER

ARMATURE

PLATE

DOOR

NUT

DOOR FRAME

DOOR FRAME

DOOR

ARMATURE PLATE

ARMATURE PLATE

MAGNET

MAGNET

DOOR

DOOR

MOUNTING
PLATE