1. Information Concerning the Operating Instructions

Please read these operating instructions carefully. Follow the information 

given. Use the operating instructions to get acquainted with the proper 

use of your Submersible pump.

**For safety reasons, people who are not familiar with these operat-

ing instructions should not use this Submersible Pump.

Following the operating instructions supplied by the manufacturer is a 

prerequisite for the proper use of the pump.

2. Application Range and Liquids to be Pumped

Submersible pumps have been designed for private use around your 

house and garden. Submersible pumps are predominantly used for drain-

age after flooding, transferring liquids, draining containers, taking water 

from wells and shafts, draining boats and yachts as well as for water 

aeration and circulation for limited period of time.

The pumps are fully submersible (waterproof sealed) and can be sub-

merged down to the following depth:  

Depth

Model #

16.5 ft 5m 

ST-900SD

23 ft

7m 

SP-550SD, SP-900SD

26 ft

8m 

SP-750TD 

Liquids which can be handled by the Submersible Pump are the follow-

ing; clean or slightly contaminated water (max. particle size 0.2”, 5mm or 

0.5mm, except the Trash Pump Model # ST-900SD which is 1.4”, 35mm) 

and soapy water. The pumps are not designed for continuous operation 

(e.g. continuous circulating operation); your pumps life will be shortened 

correspondingly by such operation.

WARNING

Corrosive, easily combustible or explosive substances 

(e.g. gasoline, petroleum, nitro thinner), fats, oils, salt and waste 

water of toilets and urinals must not be pumped.

The temperature of the liquids handled must not exceed 35ºC.

Summary of Contents for SP-550SD

Page 1: ...es at least two threads into metal and star washer or lockwasher Connectors are secured using crimping tool recommended by the manufacturer WARNING This product contains lead a chemical known to the S...

Page 2: ...ctive tools for cleaning as well as the safest By knowing how best to operate this machine you will be better positioned to show others who may also operate the unit This manual contains information f...

Page 3: ...ce line 1 866 850 6662 for information on servicing always provide the product model and identification numbers You will need to locate the model and serial number for the pump and record the informat...

Page 4: ...4 diagrams C 8 9 B 1 2 3 4 5 6 7 1 32mm 1 25mm 13mm 5 8 15mm 19mm D E...

Page 5: ...ainers taking water from wells and shafts draining boats and yachts as well as for water aeration and circulation for limited period of time The pumps are fully submersible waterproof sealed and can b...

Page 6: ...prox 21 53cm and automatically switches off at a water height of approx 2 5cm by fixing the float switch cable to the float switch lock 3 The cut in cut out height can be adjusted individually 4 3 Loc...

Page 7: ...power cable and plug before each operation A damaged pump must not be used It is absolutely neces sary to have the pump checked by your electrician Take care that the electrical connections are made...

Page 8: ...ion height is only reached in case of manual operation see point 5 Operation but not in case of auto matic operation The Submersible Pump is equipped with an automatic deaerating device whose function...

Page 9: ...Submersion Depth 23 ft 7m 26 ft 8m Contaminated Water with particle size of max 0 2 in 5mm 0 2 in 5mm SP 900SD ST 900SD Rated Power 1100W 1100W Max Delivery Capacity 4259 GPH 16500l h 4095 GPH 15500l...

Page 10: ...ion Thermal overload switch has switched the pump off due to overheating Disconnect plug and clean turbine point 8 Observe max media temp of 35 C No power Check fuses and electri cal connections Dirt...

Page 11: ...If you need assistance with the assembly or operation of your Generator please call 1 866 850 6662...

Reviews: