Rainbow 72 R NBC- Filtration & Ventilation System
Rainbow 72 R
Ventilation and Air Filtration System
for a Residential Safe Room ·
www.beind.co.il
11 |
Filter handling after use
• The filter has a very high adsorption capacity.
• At the time of an NBC attack and afterwards, do not detach the filter from the air inlet opening.
• If the filter has adsorbed NBC substances, proceed in accordance with the instructions
of the local authorities.
•
At the end of the emergency if there was no NBC attack, but the filter was attached
to the wall nonetheless, it is possible to detach it from the valve, to close the
openings with the sealing caps, and to arrange for a service check of the system.
Routine storage
• Close the air inlet valve (shock valve) by means of the decorative cover.
• Do not open or damage the original seal of the filter in any way.
• In order to maintain the proper functioning of the system, perform a service check
once every three years.
5
Connect the electric blower to the inlet valve.
6
Connect the power cord of the blower to a wall
outlet. Press the power switch on the blower.
Wait a few seconds for the blower to start operating.