7
Spillage monitoring System
This appliance is fitted with an atmospheric sensing system in the form of an oxygen sensing pilot burner. This is designed
to shut the fire off in the event of products being spilled into the room where the fire is being operated. It is important to
note that this spillage monitoring device should not be disabled or be adjusted by the installer. If the spillage monitoring
device (O.D.S pilot) is replaced it must only be exchanged with a suitable component which is supplied by Be Modern Ltd.
Combustible Shelf
This appliance may be fitted below a surround with a combustible shelf providing the following dimensional criteria is met:
There must be a minimum distance of 250mm from the top of the appliance to the underside of the shelf. The shelf must
not project more than 150mm from the mounting surface of the appliance into the room. If the shelf projects more than
150mm then the distance between the top of the appliance and the underside of the shelf must be increased accordingly;
for every 10mm of projection above 150mm the distance between the fire and shelf must be increased by 20mm
Shelf Protrusion
Min. Distance Between Fire and Shelf
150mm
250mm
160mm
270mm
170mm
290mm
180mm
310mm
190mm
330mm
200mm
350mm
Fixing the Appliance.
If the appliance is being installed with a spacer kit, this should be attached to the appliance using the screws included
and the foam seal which is supplied with the appliance should be affixed to the rear face of the spacer. Do not use any
permanent sealing substance as this will invalidate warranty as the appliance cannot be removed for periodical
inspections.
Cable Fixing System (Supplied as standard)
This appliance is best installed with the cable fitting system which is supplied in the standard fitting pack. The fitting
system comprises four (4) eyebolts, two (2) fixing cables, two (2) screwed nipples and two (2) adjuster fittings.
This installation requires that the burner tray is removed from the firebox. Remove the screws securing the burner tray
to the firebox and set the tray aside during the firebox installation.
Simply drill and fit the eyebolts in the positions shown in the next diagram.
Then thread the fixing cables through the two small holes at the top/rear of
the appliance, pass each cable through two of the eyelets then back through
one of the two holes at the rear of the appliance. Thread the cable through
the adjuster fittings. When the appliance is in its installed position, pull the
cables tight and slide the adjuster to the back of the fire—ensuring the back-
nut on the adjuster has been run as far up the thread as possible to the
hexagon shoulder. Keeping the cable tight, fit the screwed nipple to the
cable and secure. Turn the back-nut on the adjuster fixing and the cable will
be tensioned until the appliance is securely fixed.
Drill a hole 8mm
dia. by 40mm
deep. Ensure all
the
debris
is
removed
from
the hole.
Use a wrench to twist the
nut tightly until the
anchor is solid and
reliable.