background image

 

 

3 Functions and Operation 
Instruction

 

 

3.1 Startup & Shutdown Button

 

The startup & shutdown button (power button) can be used to control radio 
power-on and power-off, with specific functions as follows: 

 

Short press the startup button for about 1 second to power on, the green 

power indicator light illuminates in the case of successful power-on (under 
the condition of normal power supply). 

 

Under the condition of power-on, long press the startup button for 3 

seconds to power off, the power indicator light goes out and the display is 
closed. 

 

The function of menu parameter confirmation 

3.2 Left and Right Buttons

 

You can switch over various function menus through the left and right buttons. 

3.3 Up and Down Buttons

 

In the current menu, you can select the corresponding menu item through the 
up and down buttons. 

3.4 Data Transmitting-receiving Indicator Light 

While transmitting data, the red RX/TX indicator light illuminates; while 
receiving data, the green RX/TX indicator light illuminates.

 

3.5 GPRS and Bluetooth Operating Condition 
(Optional)

 

Include various operating conditions of the GPRS module and Bluetooth 
module shown as below, if any module is abnormal, this condition can be 
convenient for users to locating the problem: 

 

If GPRS enters the condition of network data transmission successfully, 

the red indicator light flickers once in three second; 

 

If GPRS is detecting SIM card, the red indicator light flickers twice in three 

second; 

 

If GPRS is trying to access network, the red indicator light flickers four 

times in three second; 

Summary of Contents for Harxon eRadio

Page 1: ......

Page 2: ...erred to as Harxon All rights are reserved All rights of this manual including copyright are exclusively owned by Harxon Unless permitted by the copyright owner this manual is prohibited from being copied by the means of printing duplicating or recording etc Disclaimer During the compilation this manual strives for the accuracy and completeness of contents but Harxon assumes no responsibility for ...

Page 3: ...equency Interface 11 2 3 Instruction of Indicator Lights 11 2 4 Bluetooth Module Optional 12 2 5 Network Module Optional 12 3 Functions and Operation Instruction 13 3 1 Startup Shutdown Button 13 3 2 Left and Right Buttons 13 3 3 Up and Down Buttons 13 3 4 Data Transmitting receiving Indicator Light 13 3 5 GPRS and Bluetooth Operating Condition Optional 13 3 6 Instruction of Radio Startup and Powe...

Page 4: ...1 Configuration Tool Installation 24 3 9 2 Configuration Tool s paring and connection 25 3 9 3 Radio Parameter Configuration and Query 27 3 10 Firmware Upgrade 28 Appendix A Technical Indexes 32 A 1 Specifications and Parameters of Data Transmission Radio 32 A 2 Bluetooth Parameters 33 A 3 Network Parameters 33 A 4 eRadio Suite Parts 34 A 4 1 Radio Configuration Cable HJ394 Optional 34 A 4 2 Power...

Page 5: ...Diagram Index Figure 1 eRadio 9 Figure 2 Diagram of eRadio Data Interface 11 ...

Page 6: ...rameters of Radio 32 Table 5 Specifications and Parameters of Bluetooth Module 33 Table 6 Specifications and Parameters of Network Module 33 Table 7 List of Radio Configuration Cable HJ394 Parts 34 Table 8 Definition of HJ394 Data Cable B Port 35 Table 9 List of Power Cable HJ379 Parts 36 Table 10 eRadio Background Configuration Mode Command Format 37 Table 11 List of eRadio Background Configurati...

Page 7: ...rticle3 1 b EMC RED Article3 1 a Safety RED Article3 1 a Health RoHS RoHS Directive 2011 65 EU and its amendment directives XRF screening test and Wet Chemical Testing Lead Cadmium Mercury Hexavalent Chromium PBBs PBDEs content REACH One hundred and seventy three 173 substances in the Candidate List of Substances of Very High Concern SVHC for authorization published by European Chemicals Agency EC...

Page 8: ...f the operating environment use procedure problem phenomenon before and after device abnormality as well as information such as product model product hardware version and firmware version Product model product hardware version and firmware version can be queried through eRadio configuration tools Contact Us Please contact us for more help Service Hotline 86 755 26989948 8 30 12 00 13 30 18 00 Sale...

Page 9: ...ather conditions eRadio is equipped with 3 bi color indicator lights Wireless transmitting receiving indicator light green while receiving red while transmitting Power indicator light green for normal supply red for under voltage GPRS and Bluetooth indicator light green indicator light links to GPRS red indicator light links to Bluetooth one OLED display and five buttons convenient for human compu...

Page 10: ...ction of serial port baud rate OLED display 5 user buttons One way RS232 interface Bluetooth module 4G module 3 bi color status indicator lights IP67 protection Note Optional component 1 2 Convention The following conventions are used in this manual The characters following 0x are hexadecimal digits The characters used by transmitted commands are case insensitive ...

Page 11: ... data receiving RS232 Level 4 GND 2 Signal Ground 5 TXD Serial port data transmitting RS232 Level 2 2 Radio Frequency Interface The eRadio radio frequency interface uses 50 OHM TNC negative connector 2 3 Instruction of Indicator Lights GPRS BT is GPRS and Bluetooth red and green indicator light red indicator light represents GPRS module and green one represents Bluetooth module RX TX is data trans...

Page 12: ...rrent radio supports Bluetooth users can configure and query the radio parameters by the means of Bluetooth Bluetooth V4 0 is supported 2 5 Network Module Optional If the current radio supports network data transmission users can transmit their data via network now radio can be used as CORS station without the need of RTK device thus saving cost and simplifying outdoor operation In addition networ...

Page 13: ... and right buttons 3 3 Up and Down Buttons In the current menu you can select the corresponding menu item through the up and down buttons 3 4 Data Transmitting receiving Indicator Light While transmitting data the red RX TX indicator light illuminates while receiving data the green RX TX indicator light illuminates 3 5 GPRS and Bluetooth Operating Condition Optional Include various operating condi...

Page 14: ...hreshold value 10 2V by default depending on the user s actual setting value the red power indicator light flickers once in one second If the voltage is higher than the under voltage threshold value 11 0V by default depending on the user s actual setting value the green power indicator light illuminates constantly When the voltage alarm appears if it is under voltage alarm you need add 0 3V based ...

Page 15: ...h up and down buttons and press the OK key to select this frequency as the current communication frequency point the character of will appear after selection 3 7 3 Data Protocol In this menu column you can set up the current communication protocols such as TRANSEOT TRIMTALK and TRIMMK3 Select required communication protocol through up and down buttons and press the OK key to select this protocol a...

Page 16: ...eceiving mode Now four types of transmitting receiving modes are supported transmitting receiving single transmitting single receiving and relaying mode Select required transmitting receiving mode through up and down buttons and press the OK key to select this transmitting receiving mode as the current communication transmitting receiving mode the character of will appear after selection 3 7 6 Tra...

Page 17: ...e are two options self adaptive master switch and triggering enabling The former has memory function if turning on the switch ON is displayed on the menu if off then OFF is displayed self adaptive triggering enabling does not have memory function the system remains in the startup condition after power on only if the self adaptive master switch has been turned on can the adaptive function of serial...

Page 18: ...ls 1min 5min 10min 15min 20min 25min 30min Note After the OLED display enters sleep you can awaken it through button and pop up window message 3 7 10 Interference Detection Detect whether there is any interference in the current channel You can modify the detection channel number manually and press the OK key for detection there are three levels of detection result superior moderate poor ...

Page 19: ... mode and PC configuration tool The use methods of the PC configuration tool are introduced as below The procedures of radio parameters include Communication link establishment Configuration tool installation Radio parameter query Radio parameter configuration 3 8 1 Configuration Environment Firstly build up the radio parameter configuration environment devices needed include Power supply 12V powe...

Page 20: ... end one shortcut appears on the desktop During the radio configuration later you can directly open this shortcut to operate the radio as shown in Figure 4 Figure 4 Radio Query Configuration Software Interface Note During the use of the configuration tool for radio parameter configuration and query radio is not allowed to enter the background parameter configuration mode ...

Page 21: ...stly click Read and select the right serial port number and the current operating radio serial port baud rate in the dialog box popped up click Connect and Read in the end now you can begin to read the radio configuration parameters ...

Page 22: ......

Page 23: ...n the basic information column only radio information can be queried settings are not supported In the channel information column the frequency point range set up is between 410 470MHz signs and can be used to increase and delete or reduce ...

Page 24: ...ckers twice in one second if the operating voltage of the radio is lower than wireless data transmission voltage the radio stops transmitting user data when setting up the low voltage alarm threshold value must be larger than wireless data transmission voltage 3 9 Bluetooth APP If Bluetooth connection is supported the radio could use the configuration tool Bluetooth APP provided by our company to ...

Page 25: ...e is required for the first time pairing and the default verification code is 1234 After a successful pairing the name of Bluetooth shall be displayed in the list of PAIRED DEVICES and then just click the one which you want to connect with The system will remind whether to enter the parameters configuration mode or not Click YES here Finally it will turn into the main interface and operator can co...

Page 26: ......

Page 27: ...e Basic Info Parameters in this module can be read only including the name of device model version serial number of firmware and other basic information of radio Channels Info Parameters in this module can be both read and written User can add delete or modify the corresponding frequency information according to the user s own serial number The scope of the frequency is 410 0 470 0Mhz and the maxi...

Page 28: ... sensitive maximum16 characters and the sending interval is 1 30 mins Note If current radio configuring is in PC uart and the operator also adopts the Bluetooth to configure the radio and succeeds in entering the configuration mode the PC uart will be invalid 3 10 Firmware Upgrade If the radio runs under the normal operating mode data transmission mode online upgrade for serial port is supported w...

Page 29: ...3 Select right serial port number and baud rate open the serial port and select internally installed radio as shown in Figure 5 Figure 5 Internally Installed Radio Firmware Upgrade Software Connection ...

Page 30: ...4 Select the file requiring upgrade e g F dwn ...

Page 31: ... users are required to click OK after that the system enters into the upgrade condition immediately 6 After upgrade the prompt pops up indicating successful upgrade click OK for completion of upgrade this time 7 The system powers off before powering on again if the radio has not been powered on short press the power button for 1 second before power on ...

Page 32: ...on Typical Value High transmitting power 28W 80W 12V DC Medium transmitting power 22W 65W 12V DC Low transmitting power 5W 35W 12V DC Standby 3W 12V DC Frequency Stability 1ppm Level of Three Proofings IP67 Dimension 175 L X130 W X86 5 H mm Weight About 2 0KG Operating Temperature 40 65º C Storage Temperature 50 85º C Antenna Interface TNC female connector Antenna Interface Impedance 50ohm Data In...

Page 33: ... Number Default Password 1234 Transmission Distance 30m Open environment Operating Temperature 40º C to 70º C A 3 Network Parameters Table 6 Specifications and Parameters of Network Module6 Parameter List Value Remarks 2G frequency band GSM 900 DCS1800 3G frequency band FDD B1 B8 4G frequency band FDD B1 B3 B7 B8 B20 Note The username should not be longer than 12 characters in length the serial nu...

Page 34: ... Radio Configuration Cable HJ394 Parts Mark Explanation Remarks 1 Plug 1BHTN05P 2 Rubber Coating Black 3 Cable Black 4 Cable Black 5 Rubber Coating Black 6 Bullet Terminal 1 male connector and 1 female connector respectively 7 Label MI RD HJ394 as the content 8 Screw with Internal Thread 9 Rubber Coating Black 10 Plug DB9 female connector Figure 7 HJ394 C Port Welding Surface View ...

Page 35: ...J394 Data Cable B Port Pin Name Description Remarks 2 TXD Output 3 RXD Input 5 GND GND 1 4 6 7 8 9 RSV Reserved Note After connecting to the DB9 port on PC this port can communicate normally A 4 2 Power Cable HJ379 Figure 9 Structure and Dimension of Power Cable HJ379 ...

Page 36: ...rks 1 Bullet Terminal 1 male connector and 1 female connector respectively 2 Double row cable Black 3 a Black alligator clip b Red alligator clip 4 Fuse Support 1 male connector and 1 female connector respectively 5 Fuse 32V 15A 6 Label MI RD HJ379 as the content ...

Page 37: ...onfiguration tool configuration mode Firstly the radio must run under the normal operating mode and then configure and read the radio parameters with the matched upper computer configuration tool 4 Firstly the radio must run under the normal operating mode and then upgrade the radio firmware with the matched upgrade software Under the background configuration mode configure and query the command f...

Page 38: ...eceiving frequency point is 456 05MHz One space character is between RX and receiving frequency point for separation receiving frequency point has 9 characters in length One space character is between receiving frequency point and MHz for separation Set up the current receiving frequency point rx receiving frequency point r n e g rx 456 05 r n Indicate setting up the current receiving frequency po...

Page 39: ... protocol type for separation protocol type has 8 characters in length if the name of the current protocol type has less than 8 characters in length use space characters to fill for example for protocol SOUTH there are 5 characters 3 space characters are additionally needed Current protocol setting prt protocol type r n e g prt TRIMTALK r n Indicate setting up the current radio work protocol as TR...

Page 40: ...ng mode as transmitting receiving r nPROGRAMMED OK r n Indicate the current radio operating mode is written successfully The operating modes supported are DUPLEX transmitting receiving TXONLY single transmitting RXONLY single receiving RPT radio relaying mode NETRPT network relaying mode Transmitting power query pwr r n r nPWR power level r n e g r nPWR L r n Indicate the current radio transmittin...

Page 41: ...erial port baud rate is written successfully Current work channel query channel r n e g channel 000 r n Indicate the current work is done at Channel 0 r n channel channel number r n e g r n channel 000 r n Indicate the current work is done at Channel 0 The channel number has 3 characters in length Current work channel setting channel channel number r n e g channel 0 r n Indicate setting up current...

Page 42: ...Appendix C eRadio SIM Setup ...

Page 43: ...port number Failing to sending data Inconsistent communication parameter configuration of the receiving transmitting terminal No external antenna for radio The battery voltage in the threshold value of forbidden voltage Make communication parameter configuration of the receiving transmitting terminal consistent receiving transmitting frequency point communication protocol RF baud rate operating mo...

Page 44: ......