background image

Summary of Contents for RD-3151

Page 1: ...Service Manual RD 3151 Rear Delivery Dr Assistant with Swivel Bar Rev 3 6 17 19 900 105 ...

Page 2: ...pre drilled holes Place a 1 4 Hex Screw in one corner to lightly fasten it using a 3 8 Hex Drive Repeat the process until all four screws are installed Tighten securly making sure the face plate slides in and out freely 5 Insert the umbilical tubing in first and follow with the unit 6 Mount the holder bar with holders in desired location under counter top 7 Install optional master valve assemblies...

Page 3: ...se the handpiece pressure 5 Handpiece coolant water can be turned on or off with the toggle switch located in the lower center of the faceplate 6 Water coolant flow adjustment is located to the right of the water coolant toggle switch The purge switch flushes fresh water through the water coolant system Guidelines from the Center for Disease Control CDC recommends that each handpiece be flushed pu...

Page 4: ...ve water relay valve More than one handpiece is operating A Handpiece is not all the way in the holder B Improper adjustment on pilot valve in the handpiece holder C Defective shuttle valve to gauge Insufficient water coolant A Adjust coolant flow valve B Water filter may be plugged C Handpiece may be plugged D Pinched supply tubing E Improper adjustment of water relay valve Water coolant is runni...

Page 5: ...ISTANT SWIVEL BAR RD 3151 ITEM 1 2 3 4 5 PART DESCRIPTION Syringe Holder Auto Holder Pivoting Holder Bar 10 1 2 Rear Deliver Unit Head Cabinet Wall Holder Bar 8 PART NUMBER 141 100 122 100 105 177 3100 RD 105 170 QTY 4 3 1 1 1 ...

Page 6: ...Gauge Pneumatic Indicator Chassi 3 Way Momentary Toggle Valve 3 Way Toggle Valve 3 Way Toggle Valve Needle Flow Valve Water Relay Valve Autoblock Screw 18 8 Washer 0625 OD x 199 Spacer A Series PART NUMBER 002 017 003 032 010 013 014 012 023 003 026 003 026 020 103 330 120 005 120 007 120 000 121 000 123 000 125 030 001 270 003 070 103 334 QTY 2 2 3 1 1 1 1 1 1 1 2 3 1 1 4 4 4 ...

Page 7: ... 16 x 5 16 Handpiece Actuator Lever Screw 4 x 1 2 Screw 8 x 1 2 Washer Tray Mount Spacer Automatic Holder Valve Set Screw 6 32 x 3 16 PART NUMBER 122 101 122 102 009 010 122 103 001 019 001 018 003 004 122 031 005 019 QTY 1 1 1 1 2 2 1 1 1 AUTOMATIC HANDPIECE HOLDER 122 100 ...

Page 8: ...40 x 5 8 Body Piston Diaphragm Cap Screw 6 x 1 2 Barb 10 32 x 1 16 Plastic Washer 1 4 Valve Body Spring O Ring 002 O Ring 001 Stem PART NUMBER 123 018 005 028 123 013 123 014 127 031 123 012 001 267 022 009 003 001 123 017 008 011 017 502 017 501 123 015 QTY 1 1 1 1 1 1 4 1 1 1 1 1 2 1 Water Relay Valve 123 000 Air In Water In Water Out ...

Page 9: ... 13 Drive Air In Out to Gauge Coolant Air In Coolant Water In Coolant Water Out Drive Air Out Coolant Air Out Signal Air In Handpiece Pressure Adjustment The automatic control block is the control center for your dental unit Individual handpiece pressure adjustments are located on the autoblock To adjust the pressure to each handpiece a Turn adjustment screw clockwise to decrease the handpiece pre...

Page 10: ...sher 1 4 Barb 10 32 x 1 8 O Ring 001 Stem O Ring 003 Spring O Ring 007 PART DESCRIPTION Plug Barb 10 32 x 1 16 Cap Inlet Filter Element 100 Micron O Ring 018 Filter Element 35 Micron Gauge Piston Gasket Cap Plug PART NUMBER 017 504 008 028 017 018 127 040 003 001 022 010 017 501 127 045 017 103 008 040 017 007 PART NUMBER 020 026 022 009 127 041 119 005 017 022 119 004 026 001 123 014 127 031 123 ...

Page 11: ...04 Spring O Ring Body Plastic Washer 1 4 Barb 10 32 x 1 8 Plug O Ring 001 Stem O Ring 003 PART DESCRIPTION Spring O Ring 007 Plug Cap Inlet Filter Element 100 Micron O Ring 018 Filter Element 35 Micron Gauge Piston Gasket Cap PART NUMBER 127 024 017 504 008 028 017 018 127 040 003 001 022 010 001 001 017 501 127 045 017 103 PART NUMBER 008 040 017 007 020 026 127 041 119 005 017 022 119 004 126 00...

Page 12: ... 2 1 Quick disconnect Syringe Tip Assembly 113 230 1 Remove the existing hex nut A hex nut wrench has been provided 2 Remove the syringe tip adapter using the hex wrench 3 Insert the new syringe tip adapter into the syringe head and tighten using the hex wrench 4 Place the two 2 O Rings into the syringe tip nut 5 Screw the syringe tip nut onto the syringe tip adapter and tighten using the hex wren...

Page 13: ...ing Cover Spring O Ring 012 Stem Body Poppet Spring O Ring 013 Baseplate Screw 4 40 x 1 4 Rubber Pad Screw 6 32 x 1 4 Repair kit PART NUMBER 126 260 126 200 008 005 017 012 126 005 126 004 126 006 008 006 017 013 126 003 001 005 126 007 001 004 126 025 QTY 1 1 1 1 1 1 1 1 1 1 4 1 2 ...

Page 14: ......

Page 15: ...r Regulator 127 010 W HVE Foot Control 126 000 Optional Foot Controls 126 133 Chip Blower 126 160 Wet Dry 126 203 Wet Dry Chip Blower Syringe Adjustment Block 113 026 Vacuum Cannister 131 036 S E Syringe Shuttle Valve 014 012 Auto Block 125 030 1 2 3 4 5 6 7 8 Master On Off Toggle 120 000 On Off Indicator 026 020 Purge On Off Toggle 120 000 Water On Off Toggle 120 000 HP coolant Flow 2 121 000 Air...

Page 16: ...UNDER COUNTER MOUNT TEMPLATE RD 3103 RD 3153 RD 3102 RD 3152 RD 3150 RD 3101 and RD 3151 Rev 2 6 17 19 900 283 810 11 42 2 5 FRONTEDGE OFCOUNTER 4XDRILLFOR 10WOODSCREW ...

Page 17: ...o the factory and determined to be defective will be repaired or replaced free of charge The warranty does not cover light bulbs Beaverstate Dental reserves the right to void all warranties if any product is installed by other than an authorized technician Beaverstate s war ranty does not cover damage to any surface finish including but not limited to discoloration or abrasion from cleaners disinf...

Page 18: ...Beaverstate Dental Inc 115 S Elliott Rd Newberg OR 97132 800 237 2303 503 538 8756 503 538 2845 Fax www beaverstatedental com ...