![BDH Elkay 3875A-1 Instruction Manual Download Page 2](http://html1.mh-extra.com/html/bdh/elkay-3875a-1/elkay-3875a-1_instruction-manual_2715137002.webp)
Diagram 1
Diagram 2 – Time settings
Please note:
The black bar denotes
the position of the dip switch.
Activator and Momentary Fitting
When connecting with Elkay activators use
three core cable connecting the live in,
live out and trigger terminals as shown in
Diagram 1. Please note that the TRIGGER
terminal is the third terminal between
live out and neutral. Retractive or
Momentary switches will work with this
product when looped with the live in
and trigger terminals.
Operation of the Unit
1. Press the pushbutton/touch pad and the
red LED will light up. Your light source or
appliance will now be switched ON.
2. At any time during the working of the
light source or appliance, the
pushbutton/touch pad can be pressed
to reset the timing sequence to the
originally set time, e.g. when the timing
period is 30 minutes. If pushbutton/
touch pad is pressed 15 minutes into
the sequence, the timer will re-set for a
further 30 minutes.
3. To end the timing sequence prematurely,
press and hold the pushbutton/touch
pad until the red LED fl ashes
continuously indicating the last minute
of operation. Your light source or
appliance will be switched OFF, after
one minute.
4. At one minute prior to the end of the
timing sequence, the red LED will begin
to fl ash continuously for the last
minute of operation. The blue locator
ring will then illuminate once the light
source or appliance has gone off .
LIVE IN
NEUTRAL
LIVE OUT
5 - 7m
4 - 6m
5 - 7m
3 - 4m
5 - 7m
4 - 6m
5 - 7m
3 - 4m
LIVE IN
LIVE OUT
NEUTRAL
7 metres approx
.
2.4 metres
7 metres approx.
CEILING
FLOOR
LIVE IN
NEUTRAL
LIVE OUT
LIVE IN
LIVE OUT
Battery
LIVE IN
LIVE OUT
DIL
switches
Battery
NEUTRAL
2 mins 5 mins 10 mins 15 mins 20 mins 30 mins 40 mins 60 mins
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
50 mins 60 mins 70 mins 80 mins 90 mins 100 mins 110 mins 120 mins
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
ON DIP
4
3
2
1
Brook House,
Dunmurry Industrial Estate,
Dunmurry,
Belfast BT17 9HU
T +44 (0)28 9061 6505
F +44 (0)28 9061 6518
E [email protected]
elkay.co.uk
BROOK DESIGN HARDWARE LTD
B
D
H
B
D
H
BROOK DESIGN
HARDWARE LTD
B
D
H
BROOK DESIGN
HARDWARE LTD
BDH
BROOK DESIGN
HARDWARE LTD
B
D
H
Technical Helpline
For further help or assistance or information on this or other products in the range
please call the Elkay Technical team on +44 (0)28 9061 6505. Please call the
Technical helpline before returning any products to your stockist. These instructions
are available in other languages. Please refer to our website www.elkay.co.uk
Instrukcje są również dostępne w innych językach. Prosimy o zapoznanie się z naszą
stroną internetową www.elkay.co.uk lub www.elkaypolska.pl
Important Notice
All wiring should be carried out by a competent
person or a qualifi ed electrician and should be
fi tted to current IEE wiring regulations BS 7671.
The circuit should be isolated before carrying out
any work. Failure to adhere to the instructions
will invalidate the warranty.
Elkay (Europe), 51C Milicka, Trzebnica, 55-100, Poland