BDH Elkay 370A-1 Instruction Manual Download Page 3

Step 1

Place the Live In wire into the left hand
position of the connector, the switched
Live Out wire into the second from
left position of the connector and neutral
into right hand position of connector.
(see diagram 1).

Step 2

Set the timing as per timing table  
(see diagram 3). The black square illustrates
where the dip switch should be situated.
For example: 
10min 1 = OFF, 2 = ON, 3 = OFF, 4 = OFF

Step 3

To adjust lux level (i.e. the ambient light
level at which you would like your lights to
be activated via the PIR timer) please  
refer to the lux level rotary adjuster 
diagram. Rotate the lux level adjustment 
clockwise to decrease the level of light 
required to turn the lights on and 
anticlockwise to increase the level of light 
required to turn the lights on. See diagram 
1 for position of lux level adjustment. 

Step 4

Re-apply mains supply. The blue locator 
ring will light up around the PIR button. 
Your light or appliance, will now be 
switched off. Please refer to operation 
section.

Step 5

Reduce lux level to sufficient level by
rotating clockwise towards (–) if required.
(–) represents 0 lux level.

Installation Notes

N.B. After installation the PIR will require
approximately 5 minutes to initialise.

Operation of the Unit

1.

 

In standard operation, the PIR will 

  now sense body heat when passing 

through the detection zone. Each time 
the PIR is triggered the red LED will 

  light and reset the timer back to the start 

of the timing period. The unit will then 
wait 20 seconds approximately 

  before allowing the PIR unit to sense 
  and re-trigger the timing period again.

2.

 

If no one is present in the room or the

  detection zone is not passed through,
  during its set time period the timer 
  will time out, turning off the lights or
  appliance and the blue indicator/locator
  ring will light up.

3.

 

The PIR unit will only trigger the 

  lights or appliance if the ambient light 
  level is below that set on the lux level  

adjustment.

4.

 

When the ambient light level is light

  enough so the lights would not 
  normally come on with PIR use, the 

override switch can be used turn on the 
lights for the set period time. This can 

  be used in times where addional light is 

required in a room. 

  To operate press the PIR lens, the red
  indicator LED will light to show it has 

been pressed and the timing will begin, 
in the last minute of timing the red 

  LED will flash.

Continued overleaf...

3

INSTRUCTION GUIDE

 

|

 

ILLUMINATED PIR TIMER – 3 WIRE

2 mins            5 mins         10 mins        15 mins         20 mins         25 mins         30 mins          40 mins

50 mins          60 mins         70 mins        80 mins         90 mins        100 mins       110 mins       120 mins

Reviews: