MA_DS230_C-E_27.11.2019
English
www.bdsensors.com
CS
EN
Montageanleitung /
Mounting instructions
Elektronické tlakové spína
č
e /
Electronic Pressure Switch
DS 230
Centrála východní Evropa
Headquarters Ostern Europe
BD SENSORS s.r.o.
Hradiš
ť
ská 817
CZ - 687 08 Buchlovice
Č
eská republika / Czech Republic
Tel.: +420 572 411 011
Fax: +420 572 411 497
Centrála západní Evropa /
Headquarters Western Europe
BD SENSORS GmbH
BD-Sensors-Str. 1
D - 95199 Thierstein
N
ě
mecko /
Germany
Tel.: +49 (0) 92 35 / 98 11-0
Fax: +49 (0) 92 35 / 98 11-11
Rusko /
Russia
BD SENSORS RUS
39a, Varshavskoe shosse
RU - Moscow 117105
Rusko /
Russia
Tel.: +7 (0) 9 59 81 / 09 63
Fax: +7 (0) 9 57 95 / 07 21
Tento návod k montáži je výtah z podrobného
návodu k obsluze. Ten si prosím stáhn
ě
te
z našich internetových stránek, pokud nejste
s výrobkem dob
ř
e seznámeni.
These mounting instructions are an excerpt from the complete
operating manual. It may be downloaded from our homepage,
if you are not familiar with the device.
www.bdsensors.cz
www.bdsensors.com
– Technické zm
ě
ny vyhrazeny –
– Technical modifications reserved –
WARNING! In order to avoid hazards to operators and
damages to the device, the following instructions have to
be performed by qualified technical personnel.
WARNING! Adhere to the safety and operating instructions
stated in the operation manual. Effective regulations on
occupational safety, accident prevention as well as national
installation
standards
and
approved
engineering
techniques must in addition be complied with.
Limitation of liability
If the instructions in the operating manual are not adhered
to or if the device is inappropriately used, modified or
damaged, liability is not assumed and warranty claims will
be excluded.
Intended use
Ensure that the medium is compatible with the media-
wetted parts and that the device is suitable for the
application without restrictions. The technical data listed in
the current data sheet is binding.
Product identification
Operating and display elements
▲
-button: enter operating mode
move forward in the menu system
increase the displayed value
▼
-button: enter operating mode
move backward in the menu system
decrease the displayed value
both buttons simultaneously:
confirm the menu items and set values
The device has, according to the order max. two LEDs which
are allocated to the resp. contacts. The LEDs will light up
when the respective set point has been reached and the
contact is active. The display of the measured value as well
as the configuration of the individual parameters occurs
menu-driven via the seven-segment display
.
Mounting
Wiring diagram
For the electrical connection, a shielded and twisted
multicore cable is recommended.
Pin configuration
Electrical connections
M12x1 (5-pin)
plastic
Supply –
Contact 1
Contact 2
1
3
2
4
5
Shield
via pressure port
nominal
type
ordering
serial
pressure
designation
code
number
range
signal
supply
connector pinout
LED
contact 1
LED
contact 2
4-digit seven-
segment display
▼
-button
▲
-button
unit
contact 1
V
S
A
p
I
supply –
contact 2
R
L
R
L
WARNING! Install the device only in depressurized and currentless state!
WARNING! Use a suitable seal, corresponding to the medium and the pressure input.
U
WARNING! Before the installation: make sure that the inside of the threaded neck of the closed valve is clean. If need, remove
the residual liquid in a proper way. Do not mount the device against the liquid inside the thread connection.
Connection acc. to DIN 3852
NPT connection
view X
approx. 5 Nm
approx. 30 Nm
The indicated tightening torques must not be exceeded!
DO NOT USE ANY ADDITIONAL SEALING MATERIALS; LINKE YARN; HEMP OR TEFLON TAPE
(for connection acc. DIN 3852)!
Take note that no inadmissibly high mechanical stress occurs at the pressure port, since this may cause a shifting of the
characteristic curve or to the demage. This is especially important for very small pressure ranges as well as for devices with a
pressure port made of plastic.
For more information, please read the detailed operating manual!
X
In
X
In