background image

Tx40X manual V1.06 July 2015 

 

   11 

 

 

Programming the Patrol delay (This function is only available for BBV coax):  
 

The default delay is 30 seconds.  To programme a different delay, first determine the time delay required from the table 
below: 
 
 

Preset Key 1 

Random switching from 0 to 100 seconds 

 

Preset Key 2 

12 Seconds switching 

 

Preset Key 3 

24 Seconds switching 

 

Preset Key 4 

36 Seconds switching 

 

Preset Key 5 

48 Seconds switching 

 

Preset Key 6 

60 Seconds switching 

 

Preset Key 7 

72 Seconds switching 

 

Preset Key 8 

84 Seconds switching 

 

Programming a Patrol delay on Patrol 1: 

 
Press and release the preset key that corresponds with the delay desired, then press and hold PROGRAM whilst pressing 
ZOOM IN to set patrol 1 delay.  For example, to set a delay of 12 seconds, press and release Preset Key 2, then press and 
hold PROGRAM whilst turning the joystick to ZOOM IN. 

PROGRAM

Press & release 

relevant Preset 

key

and

TWIST 

CLOCKWISE to 

ZOOM IN

 

 
 

Programming a Patrol delay on Patrol 2: 
 

Press and release the preset key that corresponds with the delay desired, then press and hold PROGRAM whilst pressing 
ZOOM OUT to set patrol 2 delay.  For example, to set a delay of 84 seconds, press and release Preset Key 8, then press and 
hold PROGRAM whilst turning the joystick to ZOOM OUT.

 

PROGRAM

Press & release 

relevant Preset 

key

and

TWIST ANTI

CLOCKWISE to 

ZOOM OUT

 

 
 

 
 

 

Summary of Contents for Tx40X

Page 1: ...Installation Guide Tx40X Telemetry transmitter Building Block Video Ltd www bbvcctv com 17 Apex Park Diplocks Way Hailsham East Sussex BN27 3JU UK Tel 44 0 1323 842727 Support 44 0 1323 444600...

Page 2: ......

Page 3: ...X connecting a Breakout box 6 Keypad functions 7 Lens action 7 Auxiliary function switches 8 Receiver self test 8 Iris level program 8 Presets 9 Patrols 10 11 Spare outputs 12 Sending Commands 12 Sele...

Page 4: ...ting condition Coax grounding If an outside cable system is connected to the unit be sure the cable system is grounded Adhere to Safety Standards All normal safety precautions as laid down by British...

Page 5: ...an control all 128 addresses of the BBV422 255 addresses of the Pelco D 32 addresses of the Pelco P Unpacking Inspect the packaging for signs of damage If damage has occurred advise the carriers and o...

Page 6: ...upply 8 NC 3 12V optional input 2 12V optional input 1 4 Break out box TxA TxB BBV Receiver Tx40X 12Vdc PSU FF FN 1 2 3 0 5 6 4 8 9 7 PROGRAM AUTOPAN Up to 1200m of twisted pair 1 2 3 0 5 6 4 8 9 7 PR...

Page 7: ...function switches on the Tx40X keypad These are IRIS OPEN IRIS CLOSE FOCUS NEAR and FOCUS FAR ZOOM IN ZOOM OUT are controlled via the joystick Clockwise will zoom in and anti clockwise with zoom out t...

Page 8: ...function is only available for BBV coax Iris Level Program This function is only available for BBV coax To preset the aperture of the iris press IRIS OPEN or IRIS CLOSE until the desired level is reac...

Page 9: ...PROGRAMMING A PRESET Position the camera using UP DOWN and LEFT RIGHT arrows Then set Zoom and Focus When satisfied with the position and the quality of the picture press and hold PROGRAM then press...

Page 10: ...tomatically removed from a patrol To remove a preset from Patrol 1 Select the preset you wish to remove from the patrol by pressing the appropriate Preset key Press and hold PROGRAM whilst pressing FO...

Page 11: ...ss and release the preset key that corresponds with the delay desired then press and hold PROGRAM whilst pressing ZOOM IN to set patrol 1 delay For example to set a delay of 12 seconds press and relea...

Page 12: ...ome menu then try 7 If this does not work either then you will need to consult the camera manufacture and enquire how to enter the menu this may not be supported by the Tx40X Protocols selection The T...

Page 13: ...d will go off while holding down the press the required camera number and release the and it will return to Example Press and hold then it will go to the tap 1 then 2 release the and it will go to and...

Page 14: ...test mode you press hold the key and apply the power When the power is applied you will see the function keys glow pink the number keys glow blue When you press the keys the back lights will go out be...

Page 15: ...with detection devices in automated system designs Presets effectively reduce reliance on the operator Rx25X The Rx25X Multiple Protocol Auxiliary Relay Receiver is designed to offer a simple cost eff...

Page 16: ...Coaxial output cards are available for up the coax control of PTZ and domes Additional alarm cards with programmable functions are available for connection of up to 16 external detection devices per...

Reviews: