![BBV SDS1 Installation Manual Download Page 3](http://html1.mh-extra.com/html/bbv/sds1/sds1_installation-manual_2714050003.webp)
SDS 1 TECHNICAL SPECIFICATION
Power Requirements
+12V dc supplied by TX1000 Base Unit
Current Consumption
50mA
(not including Keyboard)
Dimensions
L 89mm x D 89mm x H 63mm
Weight
0.2Kg
Operating Temperature Range
-10
°
C to +40
°
C
SUPPLIED MALE DB9 LEAD PIN CONFIGURATION.
Pin Number
Wire Colour
1
Red
2
Blue
3
Green
5
White
4,6,7,8 & 9
Not Connected
INTRODUCTION
The SDS1 is a serial data switch for use with the TX1000 series telemetry controllers when
using various video transmission systems or, if an extra control point is required using a slave
TX1000 Keyboard. The unit quite simply requires an “on-line” output
(normally open volt free relay
contacts)
on the video transmission transmitter or a manually operated switch in the case of a
second slave keyboard. This will switch the data flow to the TX1000 Base Unit from either the
remote site via the video transmission link or the second slave TX1000 keyboard. It is
supplied in a standard 45mm deep pattress for ease of installation and a lead for connection
to the TX1000 Base Unit is supplied. The TX1000 master keyboard will still be powered from
the TX1000 Base Unit. If the unit is used to switch to a second slave TX1000 keyboard the
second slave will need to use it’s own power supply which will be supplied.
The TX1000 Base
Unit will only supply one TX1000 keyboard, any additional keyboards will require separate
power supplies.
INSTALLATION:
SDS1 Installation Guide. Issue 1.0 27 January 1999
Page 3
Summary of Contents for SDS1
Page 5: ......