BBV CODATA Installation Manual Download Page 4

CODATA Installation Manual V2 - OCT 12.doc

- 4 -

Power cord protection -

 Power supply cords should be routed so that they are not likely

to  be  trapped,  pinched  or  otherwise  damaged  by  items  in  close  proximity  to  them,

whether inside the unit or outside it.  Particular attention should be paid to cords at plugs,
connection units and the point of exit from the unit.

Overloading -

  Do  not  overload  outlets  and  extension  cords,  as  this  can  result  in  fire  or

electric shock.

Object and liquid entry -

 Never push objects of any kind into the unit, as they may touch

dangerous  voltage  points  or  short  out  parts  that  could  result  in  fire  or  electric  shock.

Never spill liquid of any kind on or inside the unit.

Servicing -

 Servicing of the unit should only be undertaken by qualified service personnel,

as opening or removing covers may expose you to dangerous voltages or other hazards.

Damage requiring service -

 Servicing by qualified personnel should be carried out under

the following conditions:

(a)

When the power-supply cord or plug is damaged.

(b)

If liquid has been spilled or objects have fallen into the unit

(c)

If the internal electronics of the unit have been exposed to rain or water

(d)

If  the  unit  does  not  operate  normally  by  following  the  operating  instructions.
Adjust  only  those  controls  that  are  covered  by  the  operating  instructions,  as
improper adjustment of other controls may result in damage and will often require
extensive work by a qualified technician to restore the unit to normal operation.

(e)

If the unit has been dropped or the enclosure is damaged.

(f)

If the unit exhibits a distinct change in performance.  This indicates a need for
service.

Replacement  parts -

  If  replacement  parts  are  required,  ensure  that  only  replacement

parts recommended by the product manufacturer are used.

Safety  check -

  Upon  completion  of  any  service  or  repairs  to  the  unit,  safety  checks

should be performed to ensure that the unit is in proper operating condition.

Pre-installation  checks -

  It  is  recommended  that  the  unit  be  bench  tested  prior  to

installation on the site.

Safety  during  installation  or  servicing -

  Particular  care  should  be  taken  to  isolate  the

data source in order to prevent operation while engineering work is being carried out on
the CODATA.

Adhere  to  safety  standards -

  All  normal  safety  precautions  as  laid  down  by  British

Standards and the Health and Safety at Work Act should be observed.

WARNING

TO PREVENT DANGER OF FIRE OR SHOCK, DO NOT EXPOSE THE INTERNAL

COMPONENTS OF THIS EQUIPMENT TO RAIN OR MOISTURE.

Summary of Contents for CODATA

Page 1: ...Building Block Video Ltd 17 Apex Park Diplocks Industrial Estate Hailsham East Sussex BN27 3JU UK Tel 44 0 1323 842727 Fax 44 0 1323 842728 www bbvcctv com V2 CODATA Installation Guide...

Page 2: ...nual V2 OCT 12 doc 2 Contents Pre Installation Checks and Safety Procedures 3 4 Introduction 5 Technical Specification 6 Box Dimensions 7 Basic Deployment 8 Advanced Deployment 9 Cabling Recommendatio...

Page 3: ...llation or operating instructions should be adhered to Cleaning Unplug the unit from the power outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning Attac...

Page 4: ...to rain or water d If the unit does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions as improper adjustment of oth...

Page 5: ...or switch data The Omnivision CODATA transceiver modules offer a full duplex connection with data rates of up to 130MBits s over distances of 500m This technology allows the upgrade of analogue CCTV c...

Page 6: ...munication successfully established between local and remote device Dimensions 116mm w x 105mm d x 34mm h Weight 0 5kg Features Single RJ45 Socket in both transceiver modules for Ethernet connectivity...

Page 7: ...CODATA Installation Manual V2 OCT 12 doc 7 Box Dimensions...

Page 8: ...CODATA Installation Manual V2 OCT 12 doc 8 Basic Deployment...

Page 9: ...CODATA Installation Manual V2 OCT 12 doc 9 Advanced Deployment...

Page 10: ...e External Diameter Attenuation figures in dB 100m at 5Mz RG59 COAX Solid core 0 58mm Polythene Plain copper 90 coverage Black PVC UV resistant 75 1 53 pF metre nominal 6 2mm nominal 2 1 dB 100m CT125...

Page 11: ...s to be used with a number of products within the Omnivision family The mounting plate is designed to provide simple installation it will allow the mounting of the Omnivision CoData to a hard surface...

Page 12: ...tates the streaming of camera images from one or more Cisco media servers or other manufacturers NVRs or cameras without the need of a PC This enables display monitors to be mounted remotely around th...

Reviews: