Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 132 of 252
Status: 19.03.2021
SMMC
“
Terminal In
“
[SMMC input connection]
Every device can read bits from other devices, and it can read its own bits
.
Figure 115 SMMC Terminal In
A restricted number of configurable common bits for every device and this Master can be assigned
to logic as SMMC “
Terminal Out
”, and can later on be used in the functional layouts of other
Masters in these Masters‘
logic.
These elements of the bit group
SMMC “A
Termianl Out
”
connection are available in the library as
elements that can be used individually for every Master for input configuration in the function chart.
Afterwards, an instance can be generated as SMMC “
Terminal In
“ connection.
This instance can
be used as bridge in the function plans of other modules.
The connection behaves like a normal output
–
with the exception that the corresponding output
must be inserted into every Master
’s
function chart, and that it can be assigned tot he logic of the
respective function chart. The SMMC “
Terminal In
”
connection is available after the user has
configured the corresponding SMMC “
Terminal Out connection in the library of the function chart.