14
3.7 Hold
There are two different hold function. Peak hold function and data hold
function. And the setting is different accordingly.
C11=3 Automatic hold function C11=0 close hold function.
3.8 COUNT
1.At weighing mode, load the weights on the platform scal
es, Press”
Count” the indicator show” PCS 0” press” Zero” key input the quantity,
press” Print” to confirm it
2 . Load the goods on the platform scales, then the indicator will show
the quantity.
3.
Press” Count” back to weighing mode.
4. If you want to weigh different goods, at weighing mode, put the
sample on the platform scales, press” Count” the indicator show”0”
Press “ Count” hold it and then press “ ON/OFF” the indicator show”
PCS 0”, press “Zero” input the sample quantity, press “ Print” to
confirm it. Then repeat the step 2 and 3.
4. Calibration and Parameter setting
4.1 Enter setting
There have two methods to enter the setting menu:
1. when the switch “ CAL” is off, press the “PRINT” hold it and
then press” TOTAL” enter C08-39 setting.
2. Take out the sealing screw on the back of indicator, then press
“CAL” , at the “SPAN” position as below. press “PRINT” hold it and
then press “TOTAL” key , enter C01-C39 setting.