Page
7
COMPLIANCE
STANDARD
CONNECTION
DESCRIPTION
EIA
232
Serial
Connection
10/100
Base
T
Network
Port
Connection
BayTech units are in accordance with the general requirements of
Standard for Information Technology
Equipment
(ETL listed, conforms to ANSI/UL 60950-1 2
nd
Edition and CAN/CSA C22.2 No. 60950-00.
CE conforms to IEC 60950.)
Equipment installations are to be in accordance with the Canadian
Electrical Code, Part I, CSA C22.1-02; General Requirements – Canadian Electrical, Part II, CSA
C22.2 No 0-M91; the National Electrical Code, NFPA 70-2005; and the National Electrical Safety
Code, NFPA, IEEE C2-2002.
BayTech's Modular Series unit provides a Serial EIA232 interface that controls user access and outlet
controls to the power strip.
The RPC has an RJ-45 port which uses an 8-pin crossed modular cable to connect to a local EIA-232
device such as a computer terminal or external modem. Most serial computers do not have RJ-45
connections; therefore an adapter is provided with this unit to convert from a DE-9 connector to an RJ-
45 connector (Bay Tech Part No. 9FRJ45PC-4). An adapter to convert from a DB-25 connector to an
RJ-45 connector is also available from Bay Tech, upon request (Bay Tech Part No. 25FRJ45PC-4). The
8-pin crossed modular cable is configured to operate with these adapters.
Using a straight 10/100 Base-T cable, connect the RJ-45 port labeled ETHERNET on the HOST module
to an RJ-45 port on the network hub. The LINK (link integrity) LED, located on the front panel of the
HOST, illuminates when a good connection is established between the HOST and the hub.
MMPr = Modular Metered Power Redundant. This unit measures RMS voltage, and current.
Calculates power in watts and power factor efficiency per circuit. Also measures these factors for
each outlet and has Environmental Sensor, RS232 and/or Direct IP ports. Control & Non-Control
Outlets. Redundant power detects power loss or brownout conditions to switch to the secondary input
source.
We welcome any comments you may have about our products, and we hope that you will continue to
look to BayTech for your remote management needs.
CAUTION:
All power should be removed from the BayTech unit prior to removing or installing
cables and /or adapters.
ATTENTION:
Tout pouvoir doit être retiré de l'unité BayTech avant de retirer ou d'installer des
câbles et / ou des adaptateurs
NOTE:
Custom cables are available to connect a device to this unit’s serial port. These custom
cables are one-way cables labeled with Baytech on one end and a device name on the other end.
REMARQUE:
les câbles sur mesure sont disponibles pour connecter un périphérique au port
série de cet appareil. Ces câbles sont des câbles de commande à sens unique marqué par Baytech
à une extrémité et un nom de périphérique à l'autre extrémité.