7638897 - v0
2
- 14032016
16
3.2 Technical data
3.2.1 Characteristics of the appliance
Model
Unit
SPC 180 ECO
Daily electricity consumption (Qelec)
kWh
4.058
Declared load profile
L
Sound power level at 1 m indoors (
L
WA
)
dB
60
Storage volume (V)
I
180
Mixed water at 40°C (V40)
I
207
Heating power (HP)
W
1000
(1)
/ 1500
(2)
Absorbed electrical power (HP)
W
400
(1)
/ 460
(2)
COP in accordance with the EN16147 standard
2.38
(3)
/ 2.88
(4)
Maximum air flow rate
m
3
/h
350
Electrical resistor output
W
1550
Operating pressure
MPa (bar)
0.8 (8)
Power supply voltage
V
230
Circuit breaker
A
16
Heating time (10-54°C)
hours
8h39
(3)
/ 6h02
(4)
Pes
(5)
W
37.0
(3)
/ 25.0
(4)
Refrigerant fluid R-134a
kg
0.8
Weight of the tank (empty)
kg
102
Protection of the thermodynamic water heater
IP21
Sound pressure
(6)
dB(A)
46.2
Minimum water inlet pressure
MPa (bar)
0.15 (1.5)
Maximum water inlet pressure
MPa (bar)
0.65 (6.5)
(1) Value obtained at an air temperature of 7°C during heating from 10°C to 54°C
(2) Value obtained at an air temperature of 15 °C during heating from 10°C to 54°C
(3) Value obtained at an air temperature of 7°C and a water inlet temperature of 10°C according to EN16147 based on LCIE
Specifications No. 103-15/B: 2011
(4) Value obtained at an air temperature of 15°C and a water inlet temperature of 10°C according to EN16147 based on LCIE
Specifications No. 103-15/B: 2011
(5) Absorbed electrical power at stabilised rate
(6) Measure taken at 2 metres
.
3 Technical specifications