background image

1.0 Warnings

1

3

1.1

Safe Installation

1. This appliance must be installed in accordance

with the manufacturers instructions and the rules

in force. For Ireland install in accordance with

I.S.813 

“I

NSTALLATION OF

G

AS

A

PPLIANCES

. The

installation must be carried out by a CORGI

Registered Installer or other competent person

and be in accordance with the relevant

requirements of  the current 

G

AS

S

AFETY

(Installation and Use) 

R

EGULATIONS

, the 

B

UILDING

R

EGULATIONS

(Scotland) (Consolidation), the 

L

OCAL

B

UILDING

R

EGULATIONS

, the 

C

URRENT

I.E.E. W

IRING

R

EGULATIONS

and the bye laws of the Local Water

Undertaking. Where no specific instructions are

given, reference should be made to the relevant

BRITISH STANDARD CODES OF PRACTICE.

2. 

Read the instructions before installing or

using this appliance.

IMPORTANT:

The addition of anything that

may interfere with the normal operation of the

appliance without the express written

permission of Baxi UK Limited, could invalidate

the appliance warranty and infringe the Gas

Safety (Installation & Use Regulations).

WARNING: Never hang clothes or other       

items over the appliance.

1.2

In case of gas leaks

1. 

If a gas leak is found or suspected,

turn off

the gas supply at the meter immediately and

contact your Installer or Local Gas Supplier

Emergency Service (under 'Gas' in the phone

directory).

1.3

Servicing your boiler

1. We strongly recommend that your Boiler is

serviced annually by a competent person for

reasons of safety and economic. Your Installer or

British Gas Service will be able to advise you.

1.4

Electricity supply 

1. THIS APPLIANCE MUST BE EARTHED

A standard 230 volt ~ 50Hz supply is required.

The appliance must be protected by a 5 amp fuse.

“Benchmark” Installation, Commissioning and Service Record

Log Book

Please ensure that your installer has completed the Installation and

Commissioning sections of the Log Book and hands the Log Book over.

The details of the Log Book will be required in the event of any warranty

work. Keep the Log Book in a safe place and ensure that the relevant

sections are completed at each subsequent regular service visit.

WARNING:

If it is either known or suspected that a fault exists on the

appliance, it must not be used until the fault has been corrected by a
competent person.

All CORGI registered installers carry a CORGI identification card and have

a registration number. Both should be recorded in your boiler Log Book.

You can check your installer is registered by telephoning 01256 372300 or

writing to:-

1 Elmwood,

Chineham Business Park,

Crockford Lane,

Basingstoke. RG24 8WG.

Summary of Contents for Solo 3 PFL 70

Page 1: ...ating Instructions Please keep these instructions safe Should you move house please hand them over to the next occupier Baxi Solo 3 PFL System Wall Mounted Powered Flue System Boiler Gas Fired Central Heating Unit ...

Page 2: ...ed success We hope you get a satisfactory service from Baxi If not please let us know Natural Gas Baxi Solo 3 PFL System 30 G C No 41 075 25 Baxi Solo 3 PFL System 40 G C No 41 075 26 Baxi Solo 3 PFL System 50 G C No 41 075 27 Baxi Solo 3 PFL System 60 G C No 41 075 28 Baxi Solo 3 PFL System 70 G C No 41 075 29 Baxi Solo 3 PFL System 80 G C No 41 075 31 Baxi is a BS EN ISO 9001 Accredited Company ...

Page 3: ...f the gas supply at the meter immediately and contact your Installer or Local Gas Supplier Emergency Service under Gas in the phone directory 1 3 Servicing your boiler 1 We strongly recommend that your Boiler is serviced annually by a competent person for reasons of safety and economic Your Installer or British Gas Service will be able to advise you 1 4 Electricity supply 1 THIS APPLIANCE MUST BE ...

Page 4: ...ity supply to the appliance at the mains 2 Turn the thermostat knob to zero Fig 3 then turn off the gas supply at either the appliance gas cock or the meter 2 3 Frost Protection 1 The appliance incorporates a frost protection thermostat that will light the appliance when it s temperature falls to near freezing Note that this is designed to protect the boiler only the system pipework may require th...

Page 5: ... appliance or system fault is indicated 3 2 Resetting 1 To reset the device follow these instructions 2 Allow the boiler to cool if hot 3 Hinge down the lower door panel Fig 7 5 Turn the boiler thermostat control knob fully anti clockwise to the OFF position marked 0 Fig 9 6 Wait 10 seconds 7 Turn the control knob clockwise to the required thermostat setting the overheat light will go out and the ...

Page 6: ...abel affixed to the front of the boiler must be left in place to ensure future servicing is successfully undertaken 4 The compartment should be large enough to house the boiler and ancillary equipment only 5 IT SHOULD NOT BE USED AS A STORAGE CUPBOARD 6 The gas burning compartment of your boiler is completely sealed from the room in which it is fitted Products from the combustion of gas are vented...

Page 7: ...etent person should service this appliance 5 3 Guarantee 1 Your Baxi Solo 3 System is designed and produced to meet all the relevant Standards and EU directives 2 Baxi UK Limited provide a 12 month guarantee on the Boiler other parts of the system are covered by the Installer or other manufacturers The guarantee operates from the date installation is completed for the customer who is the original ...

Page 8: ...Baxi UK Limited Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN www baxi com After Sales Service 08706 096 096 Comp No 5106727 Iss 1 11 01 ...