Flue options

1.  Baxi Boilers can be fitted with flue systems as illustrated.
2.  The standard flue is suitable only for horizontal termination applications.
3.  Maximum permissible equivalent flue lengths for Solo HE 

A

 are:

Horizontal Concentric    

4 metres

Vertical Concentric 

 

4 metres

Horizontal Twin pipe 

 

75 metres (parallel pipes)

Vertical Twin pipe 

 

75 metres (parallel pipes)

4.  The elbow supplied with the standard horizontal flue kit is not included 
     in any equivalent length reductions.
     Twin Flue Pipe 

135

o

 bend (air duct) 

1.3 m

 

  135

o

 bend (flue duct) 

2.6 m

 

  91.5

o

 bend (air duct) 

4.8 m

 

  91.5

o

 bend (flue duct) 

9.6 m

     Any further “in line” bends in the flue system must be taken into consideration.
5.  The illustrations show examples of permissable flue systems.
6.  Instructions for guidance and fitting are included in each kit, where appropriate.

1.

Baxi Boilers can be fitted with flue systems as illustrated.

2.

The standard flue is suitable only for horizontal termination
applications.

3.

Maximum permissible equivalent flue lengths for Solo HE

A

are:

Horizontal Concentric 4 metres
Vertical Concentric 4 metres
Horizontal Twin pipe 75 metres (parallel pipes)
Vertical Twin Pipe

75 metres (parallel pipes)

4.

The elbow supplied with the standard horizontal flue kit is
not included in any equivalent length reductions.

Twin Flue Pipe

135° bend (air duct)

1.3 m

135° bend (flue duct) 2.6 m
91.5° bend (air duct) 4.8 m
91.5° bend (flue duct) 9.6 m

Any further "in line" bends in the flue system must be taken into
consideration.

5.

The illustrations show examples of permissible flue systems.

6.

Instructions for guidance and fitting are included in each kit,
where appropriate.

Flue Options

Flue Options

Key

Item Description

Specification

OD

Multifit

Dimensions

Sales Code

Standard Horizontal Flue inc Elbow

850mm

110mm

236921

Horizontal Flue / Wall Terminal

850mm

110mm

243013BAX

Vertical Flue Adaptor (Boiler)

110mm

5106888

Flue Extension

1000mm

110mm

241695

Flue Extension

500mm

110mm

241694

Flue Extension

250m

110mm

241692

Flue Bend

93 degree

110mm

241687

Flue Bend (Pair)

135 degree

110mm

241689

Not illustrated

Pipe Support

110mm

243014BAX

Not illustrated

Flue Terminal Deflector

248167

NOTE: The 3 degree fall back on concentric flues can be reduced to 1.5 degree providing the flue system is adequately clamped in accordance with
the installation instructions.

Key

Item Description

Specification

OD

Multifit

Dimensions

Sales Code

Vertical Roof Terminal

70/110mm

242802

Vertical Flue Adaptor (Boiler)

110mm

5106888

Flue Extension

1000mm

110mm

241695

Flue Extension

500mm

110mm

241694

Flue Extension

250m

110mm

241692

Flue Bend

93 degree

110mm

241687

Flue Bend (Pair)

135 degree

110mm

241689

Not illustrated

Pipe Support

110mm

243014BAX

Pitched Roof Flashing

25/50 degree

125mm

243015

Flat Roof Flashing

125mm

243016BAX

Not illustrated

Roof Cover Plate

243131

GROUP B

Concentric Horizontal Flue System 70/110mm diameter for use with Solo HE

A

GROUP B

Concentric Vertical Flue System 70/110mm diameter for use with Solo HE

A

6

Baxi Range guide _ 8pageqx7.qxp:17645_BAXI_RANGE_44PP_BROCH  22/8/11  13:35  Page 6

Key

Item Description

Specification 

OD
Dimensions 

Multifit
Sales Code 

Standard Horizontal Flue inc Elbow

850mm

110mm

236921

Horizontal Flue/Wall Terminal

850mm

110mm

243013BAX

Vertical Flue Adaptor (Boiler)

110mm

5106888

Flue Extension

1000mm

110mm

241695

Flue Extension

500mm

110mm

241694

Flue Extension

250m

110mm

241692

Flue Bend

93 degree

110mm

241687

Flue Bend (Pair)

135 degree

110mm

241689

Not illustrated

Pipe Support

110mm

243014BAX

Not illustrated

Flue Terminal Deflector

248167

NOTE: The 3 degree fall back on concentric flues can be reduced to 1.5 degrees providing the flue system is adequately clamped in accordance with
the installation instructions.

GROUP B

 

Concentric Horizontal Flue System 70/110mm diameter for use with Solo HE 

A

1.

Baxi Boilers can be fitted with flue systems as illustrated.

2.

The standard flue is suitable only for horizontal termination
applications.

3.

Maximum permissible equivalent flue lengths for Solo HE

A

are:

Horizontal Concentric 4 metres
Vertical Concentric 4 metres
Horizontal Twin pipe 75 metres (parallel pipes)
Vertical Twin Pipe

75 metres (parallel pipes)

4.

The elbow supplied with the standard horizontal flue kit is
not included in any equivalent length reductions.

Twin Flue Pipe

135° bend (air duct)

1.3 m

135° bend (flue duct) 2.6 m
91.5° bend (air duct) 4.8 m
91.5° bend (flue duct) 9.6 m

Any further "in line" bends in the flue system must be taken into
consideration.

5.

The illustrations show examples of permissible flue systems.

6.

Instructions for guidance and fitting are included in each kit,
where appropriate.

Flue Options

Flue Options

Key

Item Description

Specification

OD

Multifit

Dimensions

Sales Code

Standard Horizontal Flue inc Elbow

850mm

110mm

236921

Horizontal Flue / Wall Terminal

850mm

110mm

243013BAX

Vertical Flue Adaptor (Boiler)

110mm

5106888

Flue Extension

1000mm

110mm

241695

Flue Extension

500mm

110mm

241694

Flue Extension

250m

110mm

241692

Flue Bend

93 degree

110mm

241687

Flue Bend (Pair)

135 degree

110mm

241689

Not illustrated

Pipe Support

110mm

243014BAX

Not illustrated

Flue Terminal Deflector

248167

NOTE: The 3 degree fall back on concentric flues can be reduced to 1.5 degree providing the flue system is adequately clamped in accordance with
the installation instructions.

Key

Item Description

Specification

OD

Multifit

Dimensions

Sales Code

Vertical Roof Terminal

70/110mm

242802

Vertical Flue Adaptor (Boiler)

110mm

5106888

Flue Extension

1000mm

110mm

241695

Flue Extension

500mm

110mm

241694

Flue Extension

250m

110mm

241692

Flue Bend

93 degree

110mm

241687

Flue Bend (Pair)

135 degree

110mm

241689

Not illustrated

Pipe Support

110mm

243014BAX

Pitched Roof Flashing

25/50 degree

125mm

243015

Flat Roof Flashing

125mm

243016BAX

Not illustrated

Roof Cover Plate

243131

GROUP B

Concentric Horizontal Flue System 70/110mm diameter for use with Solo HE

A

GROUP B

Concentric Vertical Flue System 70/110mm diameter for use with Solo HE

A

6

Baxi Range guide _ 8pageqx7.qxp:17645_BAXI_RANGE_44PP_BROCH  22/8/11  13:35  Page 6

GROUP B

 

Concentric Vertical Flue System 70/110mm diameter for use with Solo HE 

A

Key

Item Description

Specification 

OD
Dimensions 

Multifit
Sales Code 

Vertical Roof Terminal

70/110mm

242802

Vertical Flue Adaptor (Boiler)

110mm

5106888

Flue Extension

1000mm

110mm

241695

Flue Extension

500mm

110mm

241694

Flue Extension

250m

110mm

241692

Flue Bend

93 degree

110mm

241687

Flue Bend (Pair)

135 degree

110mm

241689

Not illustrated

Pipe Support

110mm

243014BAX

Pitched Roof Flashing

25/50 degree

125mm

243015

Flat Roof Flashing

125mm

243016BAX

Not illustrated

Roof Cover Plate

243131

Key

Item Description

Specification

OD

Multifit

Dimensions

Sales Code

Plume Displacement Kit inc Elbow & Clips

110mm

5121371

Plume Displacement Kit Extension & Clip

1000mm

70mm

5121372

Plume Displacement Kit Bend

93 degree

70mm

5121373

Plume Displacement Kit Bend (Pair)

135 degree

70mm

5121374

GROUP L

Plume Displacement Kits 70/110mm diameter for use with Solo HE

A

Key

Item Description

Specification

OD

Multifit

Dimensions

Sales Code

Vertical Roof Terminal

70/110mm

242802

Horizontal / Wall Terminal

850mm

110mm

243013BAX

Twin Pipe Flue Adaptor Set

242757

Twin Pipe Flue Extension

250mm

80mm

246135

Twin Pipe Flue Extension

500mm

80mm

246136

Twin Pipe Flue Extension

1000mm

80mm

246137

Twin Pipe Flue Bend (Pair)

90 degree

80mm

5121560

Not illustrated

Twin Pipe Flue Bend (Pair)

135 degree

80mm

5121561

Not illustrated

Pipe Support

110mm

243014BAX

Not illustrated

Twin Pipe Support (Pair)

80mm

5111081

Pitched Roof Flashing

25/50 degree

125mm

243015

Not illustrated

Flat Roof Flashing

243016BAX

Not illustrated

Flue Terminal Deflector

248167

Not illustrated

Roof Cover Plate

243131

GROUP P

Twin Flue System 80/80mm diameter for use with Solo HE

A

7

Support

With call service support available 7 days a
week, 363 days a year,

heateam

offers quick

and effective servicing and maintenance
support through over 280 highly trained
heating experts across the country. 

The Baxi trade technical helpline offers a range of free services to
Baxi installers:

• In-warranty support
• Help with installation problems
• Boiler selection advice
• Fault-finding assistance
• Flue queries

The service division of Baxi Group

heateam

achieved seventh place in the 2010

Top 50 Call Centres for Customer Service
following the UK's biggest ever call centre
benchmarking exercise.

The study was conducted by independent
market research company GfK, who made
18,500 mystery shopper enquiries to the call
centres to identify the best performers. Each
call centre was rated, using over 50 criteria,
on timeliness, ease of use, reliability, staff knowledge and
personal service and awarded a customer service rating.  

heateam

has been been given this award for the last two years

showing on-going commitment to providing  top class service to
all its customers.

Baxi Range guide _ 8pageqx7.qxp:17645_BAXI_RANGE_44PP_BROCH  22/8/11  13:35  Page 7

GROUP L

 

Plume Displacement Kits 70/110mm diameter for use with Solo HE 

A

Key

Item Description

Specification 

OD
Dimensions 

Multifit
Sales Code 

Plume Displacement Kit inc Elbow & Clips

110mm

5121371

Plume Displacement Kit Extension & Clip

1000mm

70mm

5121372

Plume Displacement Kit Bend

93 degree

70mm

5121373

Plume Displacement Kit Bend (Pair)

135 degree

70mm

5121374

Key

Item Description

Specification

OD

Multifit

Dimensions

Sales Code

Plume Displacement Kit inc Elbow & Clips

110mm

5121371

Plume Displacement Kit Extension & Clip

1000mm

70mm

5121372

Plume Displacement Kit Bend

93 degree

70mm

5121373

Plume Displacement Kit Bend (Pair)

135 degree

70mm

5121374

GROUP L

Plume Displacement Kits 70/110mm diameter for use with Solo HE

A

Key

Item Description

Specification

OD

Multifit

Dimensions

Sales Code

Vertical Roof Terminal

70/110mm

242802

Horizontal / Wall Terminal

850mm

110mm

243013BAX

Twin Pipe Flue Adaptor Set

242757

Twin Pipe Flue Extension

250mm

80mm

246135

Twin Pipe Flue Extension

500mm

80mm

246136

Twin Pipe Flue Extension

1000mm

80mm

246137

Twin Pipe Flue Bend (Pair)

90 degree

80mm

5121560

Not illustrated

Twin Pipe Flue Bend (Pair)

135 degree

80mm

5121561

Not illustrated

Pipe Support

110mm

243014BAX

Not illustrated

Twin Pipe Support (Pair)

80mm

5111081

Pitched Roof Flashing

25/50 degree

125mm

243015

Not illustrated

Flat Roof Flashing

243016BAX

Not illustrated

Flue Terminal Deflector

248167

Not illustrated

Roof Cover Plate

243131

GROUP P

Twin Flue System 80/80mm diameter for use with Solo HE

A

7

Support

With call service support available 7 days a
week, 363 days a year,

heateam

offers quick

and effective servicing and maintenance
support through over 280 highly trained
heating experts across the country. 

The Baxi trade technical helpline offers a range of free services to
Baxi installers:

• In-warranty support
• Help with installation problems
• Boiler selection advice
• Fault-finding assistance
• Flue queries

The service division of Baxi Group

heateam

achieved seventh place in the 2010

Top 50 Call Centres for Customer Service
following the UK's biggest ever call centre
benchmarking exercise.

The study was conducted by independent
market research company GfK, who made
18,500 mystery shopper enquiries to the call
centres to identify the best performers. Each
call centre was rated, using over 50 criteria,
on timeliness, ease of use, reliability, staff knowledge and
personal service and awarded a customer service rating.  

heateam

has been been given this award for the last two years

showing on-going commitment to providing  top class service to
all its customers.

Baxi Range guide _ 8pageqx7.qxp:17645_BAXI_RANGE_44PP_BROCH  22/8/11  13:35  Page 7

Key

Item Description

Specification 

OD
Dimensions 

Multifit
Sales Code 

Vertical Roof Terminal

70/110mm

242802

Horizontal/Wall Terminal

850mm

110mm

243013BAX

Twin Pipe Flue Adaptor Set

242757

Twin Pipe Flue Extension

250mm

80mm

246135

Twin Pipe Flue Extension

500mm

80mm

246136

Twin Pipe Flue Extension

1000m

80mm

246137

Twin Pipe Flue Bend (Pair)

90 degree

80mm

5121560

Not illustrated

Twin Pipe Flue Bend (Pair)

135 degree

80mm

5121561

Not illustrated

Pipe Support

110mm

243014BAX

Not illustrated

Twin Pipe Support (Pair)

80mm

5111081

Pitched Roof Flashing

25/50 degree

125mm

243015

Not illustrated

Flat Roof Flashing

243016BAX

Not illustrated

Flue Terminal Deflector

248167

Not illustrated

Roof Cover Plate

243131

GROUP P

 

Twin Flue System 80/80mm diameter for use with Solo HE 

A

Solo installer brochure 8pages.indd   5

17/08/2012   17:06

Summary of Contents for Solo 12 HE

Page 1: ...SOLO HE A Compact heat only boiler www baxi co uk ...

Page 2: ... of engineering experience and industry firsts We were producing heating boilers before the first motor car was built or the first electric light bulb illuminated We re very proud of our long heritage of quality and innovation and that we continue to manufacture here in the UK All Baxi GAboilers are Energy Saving Trust Recommended products to give your customer added peace of mind The company is f...

Page 3: ...lace any existing heat only boiler Energy Saving Trust Recommended Two year parts and labour warranty giving customers complete peace of mind through our award winning customer service division heateam 2 www baxi co uk The simple contemporary lines and soft curves are bound to appeal to customers as will the beautifully simple controls that make it easy to use Its clean compact space saving design...

Page 4: ... x 0 75mm2 Power Consumption 80 80 80 80 80 External Fuse Rating 3 3 3 3 3 Internal Fuse Rating 3 15 3 15 3 15 3 15 3 15 Ingress Protection Rating without electro mechanical timer fitted IPX2 IPX2 IPX2 IPX2 IPX2 Integral Boiler Only Frost Thermostat No No No No No Pump Overrun No No No No No MECHANICAL HYDRAULIC Compartment Ventilation Required None None None None None Flow Return Pipe Size 22 22 ...

Page 5: ...BAX Not illustrated Flue Terminal Deflector 248167 NOTE The 3 degree fall back on concentric flues can be reduced to 1 5 degree providing the flue system is adequately clamped in accordance with the installation instructions Key Item Description Specification OD Multifit Dimensions Sales Code Vertical Roof Terminal 70 110mm 242802 Vertical Flue Adaptor Boiler 110mm 5106888 Flue Extension 1000mm 11...

Page 6: ...giving them complete peace of mind Once this initial warranty has expired they have the option of extending it Aftersales service heateam our award winning customer service division is our team of 270 Gas Safe registered engineers working across the UK to ensure your customers are happy with their investment in their Baxi boiler In fact it s like having your very own aftersales team Any problems e...

Page 7: ...ly in the current economic climate That s why we ve set up works our great new business support scheme Far more than a loyalty programme works rewards genuine two way communication between you and Baxi Rewards Earn Business Points to spend on a range of gifts and business support Free Gas Safe notification Save time and money on Gas Safe notifications with works easy online process Next day call o...

Page 8: ... recorded Contact us Baxi Brooks House Coventry Road Warwick CV34 4LL www baxi co uk This Brochure is printed on paper sourced from well managed forests controlled sources This Brochure is printed using vegetable based inks Please recycle this Brochure when you have finished with it Baxi policy is one of continual improvement and development The right to change specification and appearance without...

Reviews: