4

EcoBlue Accessories

1. Introduction

7212551

Warning

Danger! Risk of electric shock! Installation must be carried out by a person competent to do so!

Before removal from backplate, the device must be disconnected from the power supply!

Interferences and changes to the device will invalidate the warranty and guarantee rights.

Maximum diameter of the cable for the terminals is 2 x 2.5 mm

2

.

Read and observe these instructions fully to ensure the correct operation of the device and a safe

operation.

1.1 General energy information

What is a programmer?...an Explanation for Householders

(as recommended by the Energy Savings Trust)

Programmers allow you to set ‘ON’ and ‘OFF’ time periods. Some models switch the central

heating and domestic hot water on and off at the same time, while others allow the domestic hot

water and heating to come on and go off at different times. Set the ‘ON’ and ‘OFF’ time periods to

suit your own lifestyle. On some programmers you must also set whether you want the heating and

hot water to run continuously, run under the chosen ‘ON’ and ‘OFF’ heating periods, or be

permanently off.

The time on the programmer must be correct. Some types have to be adjusted in spring and

autumn at the changes between Greenwich Mean Time and British Summer Time. You may be

able to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’, or ‘Boost’.

These are explained in the manufacturer’s instructions. The heating will not work if the room

thermostat has switched the heating off. And, if you have a hot-water cylinder, the water heating

will not work if the cylinder thermostat detects that the hot water has reached the correct

temperature. 

1.2 Description of the device

Your single channel programmer provides timing control for your central heating, letting you set ON

and OFF periods to suit your own lifestyle.

Backlit LCD Display

Real Time Clock

Up to 3 ON/OFF per day

Automatic summertime / wintertime changeover

Daily, weekly and week-weekend programming possibility

Different running modes: OFF, AUTO, ONCE, CONTINUOUS and HOLIDAYS

Manual override function

Manual extra hour function

3 different pre-programmed profiles, customisable by user

Summary of Contents for Single Channel Digital Programmer

Page 1: ...he Boiler Installation and Service Instructions Please leave with the user when completed Instruction manual for Installers and Users Single Channel Digital Programmer Override Extra Hour Mode DAY PROG RUN TIME OK Holidays OFF am Thu AUTO ONCE CONT EXT HOUR 1 2 3 ON1 Select ...

Page 2: ...2 EcoBlue Accessories 7212551 ...

Page 3: ... functions 7 3 3 Commissioning 8 3 4 To alter the time and date 9 3 5 To show a digital time display and change AM PM time display to 24 hour clock 10 4 Setting the Heating Programmes 4 1 Running a default programme 11 4 2 Selecting a programme type and a default programme 12 4 3 Weekly programming days or blocks 13 4 4 5 2 programming 13 4 5 Daily programming 13 4 6 Setting time periods 14 5 Oper...

Page 4: ...ant the heating and hot water to run continuously run under the chosen ON and OFF heating periods or be permanently off The time on the programmer must be correct Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time You may be able to temporarily adjust the heating programme for example Override Advance or Boost These are explained ...

Page 5: ...Power reserve 2h Switching capacity 3 A 250 V resistive cos φ 1 3 A 250 V inductive cos φ 0 6 Time display 24 h or 12 h AM PM format Time setting resolution Time of day 1 min Programmes min switching 1 min Programmes Selectable daily weekly or week weekend Number of switchings per day 3 ON OFF pairs 2 ON OFF pairs selectable Operating temperature range 0 C 45 C Ambient temperature 20 C 55 C Humidi...

Page 6: ...Wiring can be routed from behind or if surface mounted through the breakout tab to the left of the retaining screw at the bottom of the back plate Fix the backplate to the wall using the screws provided Connect the wiring into the backplate connectors as shown in Fig 3 The input to terminal 1 may be supplied from the mains supply or from the boiler wiring connections as appropriate to the applianc...

Page 7: ...operating mode indicator D Central heating override button E Central heating extra hour button F Central heating operating mode button G Central heating indicator lamp H Central heating extra hour indication I Central heating programming period indication J Select indicator lamps K Select L OK button M and button N1 Holiday button O1 Holiday icon P Information text line Q Analogue clock current ti...

Page 8: ...th and buttons and confirm with OK OK 1 Select month with and buttons and confirm with OK OK 3 Select year with and buttons and confirm with OK OK 4 Select hour with and buttons and confirm with OK OK 5 Select minutes with and buttons and confirm with OK OK 6 The date and time are saved The programmer goes to RUN mode OK 7 8 EcoBlue Accessories 3 Operation Configuration 3 3 Commissioning Connect t...

Page 9: ...ay with and buttons and confirm with OK OK 2 Select month with and buttons and confirm with OK OK 3 Select year with and buttons and confirm with OK OK 4 Select hour with and buttons and confirm with OK OK 5 Select minutes with and buttons and confirm with OK OK 6 The date and time are saved Press the right hand SELECT button to select RUN mode OK 7 DAY PRG RUN Select TIME ...

Page 10: ...e AM PM time display to 24 hour clock 7212551 DAY PRG RUN Select TIME OK 1 OK 2 OK 3 Press the SELECT buttons until RUN light is lit Press and hold buttons together for 10 seconds Press OK Press OK OK 4 Press OK 5 Press OK OK 6 Press OK OK 7 Press or OK 8 Press OK Press seven times to exit menu ...

Page 11: ...m Default programme ECO Daily ON1 06 30 am ON2 12 00pm ON3 05 30 pm OFF1 07 30 am OFF2 12 00pm OFF3 10 00 pm Weekly ON1 08 30 am ON2 12 00pm ON3 05 30 pm OFF1 09 30 am OFF2 01 00pm OFF3 10 00 pm 5 2 ON1 06 30 am ON2 12 00pm ON3 05 30 pm Mon Fri OFF1 07 30 am OFF2 12 00pm OFF3 10 00 pm ON1 08 30 am ON2 12 00pm ON3 05 30 pm Sat Sun OFF1 09 30 am OFF2 01 00pm OFF3 10 30 pm Three programme types are p...

Page 12: ...s four times until program type is displayed Press OK With the buttons scroll through and select programme type Press OK to select OK 5 OK 6 Press OK 7 With the buttons scroll through and select setting STD HOME or ECO Press OK to select Press twice to leave menu Press OK to select Press the SELECT buttons until RUN light is lit Press and hold buttons together for 10 seconds ...

Page 13: ...PRG light is lit On 5 2 programme Monday Friday can be selected and Saturday Sunday selected as separate blocks Use to choose the required block of days Press OK Go to Section 4 6 OK Mon 2 To set the programmer for more than one day press OK OK Mon 4 OK Mon Tue Days 3 Use to choose additional days Press OK Repeat this process until all the desired days have been selected On the last day selected c...

Page 14: ...Fri Sat Sun Wed Tue Mon OFF2 pm 4 Press to adjust OFF2 time Press OK Press to adjust ON2 time Press OK OK Thu Fri Sat Sun Wed Tue Mon ON3 pm DAY PRG RUN Select TIME 5 OK Thu Fri Sat Sun Wed Tue Mon OFF3 pm 6 7 Press to adjust OFF3 time Press OK The screen returns to SELECT DAYS or to ON1 for DAILY programmes Press the SELECT buttons until RUN light is lit The programme is now saved Press to adjust...

Page 15: ... is running in AUTO and ONCE operating mode Press OVERRIDE once to activate Press OVERRIDE again to cancel 5 3 Extra hour mode The extra hour button allows you to switch the system ON for up to 3 extra hours without altering the programme When the blue central heating indicator lamp is OFF pressing the EXTRA HOUR button switches the heating ON for just one hour When the blue central heating indica...

Page 16: ...the device is working in RUN mode 2 Press the HOLIDAY button 3 Select desired numbers of days or and confirm with OK Holiday mode is activated To cancel the Holiday function just press the HOLIDAY button again If you use the holiday function during winter you should ensure that you have a secondary frost protection device in your system to prevent frost damage DAY PRG RUN Select TIME OK OFF AUTO O...

Page 17: ... green indicator lamp RUN must be ON To save your settings continue scrolling through the menu options with key until you once again see INST MENU OK and leave the installer s menu with the key To cancel the installer s menu press the select button The following settings are possible DAY PRG RUN Select TIME OK 1 OK 2 OK 3 Press the SELECT buttons until RUN light is lit Press and hold buttons toget...

Page 18: ... must be done manually PROG TYPE Menu to select daily week weekend weekly programming This value will be applied by central heating programming method Setting possibilities Daily All days Monday Sunday are programmed with the same ON OFF time schedule Weekly You can program each day Monday Tuesday with a different ON OFF time schedule 5 2 You can program Monday Friday with a ON OFF time schedule a...

Page 19: ...7212551 6 2 Disposal Dispose of the packaging materials correctly according to legal requirements and regulations Please recycle where possible Do not throw electrical and electronic components in the bin These should be taken to a recycling centre ...

Page 20: ...provements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject to our standard Conditions of Sale which are available on request 7212551 1 03 14 BAXI A Trading Division of Baxi Heating UK Ltd 3879156 Brooks House Coventry Road Warwick CV34 4LL Website www baxi co uk e oe ...