Baxi Neta-tec Plus Features And Specifications Download Page 2

Technical specifications

Neta-tec Plus 

Combi 24 GA 

Neta-tec Plus 

Combi 28 GA 

Neta-tec Plus 

Combi 33 GA 

Sales Code

Boiler only

7210899

7210901

7210903

Std. Flue

720870201

720870201

720870201

Boiler with Std. Flue

7210905

7210906

7210907

Controls

Concealed User Controls

Yes

Yes

Yes

User Adjustable DHW Temperature

Yes

Yes

Yes

User Adjustable CH Temperature

Yes

Yes

Yes

LCD Control Panel Temp/Status/Fault Diagnosis Display

Yes

Yes

Yes

Performance

Heat Output CH 

kW (Max)

20

24

28

kW (Min)

3.4

3.8

4.7

Heat Output DHW

Output - kW (Max)

24

28

33

Maximum DHW Flow Rate (Delta T @ 35

o

 Max)

l/min

9.8

11.5

13.5

Minimum DHW Flow Rate Required

l/min

2

2

2

Minimum Operating DHW Pressure Required

bar

0.15

0.15

0.15

SEDBUK 2005 Seasonal Efficiency NG/LPG

%

91.1/93.2

91.1/93.2

91.1/93.2

SEDBUK 2009 Seasonal Efficiency NG/LPG

%

88.9/91.0

89.0/91.0

89.0/90.9

NOx Class (5 being lowest)

1 - 5

5

5

5

NOx Emission

mg/kW/h

16.1

19.3

17

CO Emission

mg/kW/h

5.1

8

7.5

Gas

 

Gas Supply Pipe Size

(mm)

22

22

22

NG & LPG (Propane) Compatible (Single Product)

Yes

Yes

Yes

Nominal Gas Inlet Pressure

NG/LPG (mbar)

20/37

20/37

20/37

Maximum Gas Rate (NG/Propane) after 10 mins

m

3

/hr

2.5/1.92

3.0/2.25

3.5/2.64

Electrical

Electrical Supply

Volts/Hz

230V/50Hz

230V/50Hz

230V/50Hz

Permanent Live Required

Yes

Yes

Yes

Electrical Cable Required

(Core)

3 x 0.75

3 x 0.75

3 x 0.75

Power Consumption

Watts

104

116

133

External Fuse Rating

Amps

3

3

3

Boiler IP Rating 

Approval Category

IPX5D

IPX5D

IPX5D

Mechanical & Hydraulic Connections

CH Flow/Return Pipe Size

(mm)

22

22

22

DHW Flow/Inlet/PRV Size

(mm)

15

15

15

Condensate Discharge Pipe Size

(mm)

21.5

21.5

21.5

Installation

24 hr Pump Exercise

Yes

Yes

Yes

Pump Overrun

Yes

Yes

Yes

System Filling Loop

Standard

Standard

Standard

Integral System Pump

2 Speed

2 Speed

2 Speed

Integral ‘Boiler Only’ Frost Thermostat 

Yes

Yes

Yes

Pre-plumb Jig Available

Yes

Yes

Yes

Stand off Bracket (Optional)

Yes

Yes

Yes

Installer Lift Weight

Max (kg)

34

34

36

Flue Systems

Max Horizontal Ø60/100

m

10

10

10

Max Vertical Ø60/100

m

10

10

10

Max Horizontal Ø80/125

m

20

20

20

Max Vertical Ø80/125

m

20

20

20

Twin-pipe Horizontal Ø80/80

m

15

15

15

Twin-pipe Vertical Ø80/80

m

15

15

15

Plume Management Kit (Max Length)

m

8

8

8

For more information call 0844 871 1525 or visit www.baxi.co.uk

Neta-tec-Plus-Data-SheetV2.indd   2

14/11/2012   15:49

Reviews: