background image

Evacuated Tube  Collector
East West Array

THESE INSTRUCTIONS SHOULD BE READ IN CONJUNCTION WITH THE 

Baxi Solarflo

TM

Installation Guide (Part No. 5130226) and Commissioning Guide (Part No. 5130227).

Please leave these instructions with the 
User for Safe Keeping

The User Guide 

(Part No. 5130229) covers the

controller functionality of this kit.

External fixing methods for 

Pitched Roof, ‘A’ Frame or 

Facade Floor are covered in the

instructions (Part No. 5130229,

5130330, 5130331)

I N S T A L L A T I O N   &   C O M M I S S I O N I N G

G U I D A N C E   N O T E S

Summary of Contents for MULTIFIT Evacuated Tube Collector

Page 1: ...Guide Part No 5130227 Please leave these instructions with the User for Safe Keeping The User Guide Part No 5130229 covers the controller functionality of this kit External fixing methods for Pitched...

Page 2: ...tion can be obtained by placing one solar collector on a opposite roof aspects one facing east the other facing west In this manner the suns energy can be utilised throughout the day The standard sola...

Page 3: ...pipe runs between collectors should be as short as possible For system controller wiring of the east west array refer to the back page 1 Cold Supply for Domestic Hot Water 2 Domestic Hot Water Outlet...

Page 4: ...luid level should be monitored during the fill procedure If the fluid level gets near to the bottom of the suction hose approximately 1 litre is left in the container it will be necessary to stop the...

Page 5: ...l there is a clear flow of fluid The fill process should be run for several minutes to ensure the system is flushed of debris and all air is removed The debris should be caught within the inline filte...

Page 6: ...1 After flushing and filling the solar primary system with heat transfer fluid the pressure must be checked 2 Pressure test the system to between 2 to 2 5 bar Observe the maximum pressure ratings of...

Page 7: ...ation flow rate through the flow meter sight glass Fig 5 Item 7 7 Adjust screw of the flow limiter with a screwdriver until the upper edge of the float in the sight glass indicates the required flow r...

Page 8: ...ets mounted on the collector Refer to the relevant Collector Mounting Installation Guide for details of the position of the sensor pockets Only the BLACK sleeved sensors should be used in the collecto...

Reviews: