14 Appendix
14.1 Product fiche
Tab.86 Product fiche for heat pump combination heaters
Platinum BC
iPlus V200
Smart 4.5
Platinum BC
iPlus V200
Smart 6
Platinum BC
iPlus V200
Smart 8
Space heating - Temperature application
Medium
Medium
Medium
Water heating - Declared load profile
L
L
L
Seasonal space heating energy efficiency class under average
climate conditions
A
++
A
++
A
++
Water heating energy efficiency class under average climate
conditions
A
+
A
+
A
+
Rated heat output under average climate conditions
(Prated or
Psup)
kW
3
4
6
Space heating - Annual energy consumption under average cli
mate conditions
kWh
1934
2501
3568
Water heating - Annual energy consumption under average cli
mate conditions
kWh
769
787
833
Seasonal space heating energy efficiency under average climate
conditions
%
125
126
126
Water heating energy efficiency under average climate condi
tions
%
133.00
130.00
123.00
Sound power level L
WA
dB
30
35
34
Ability to off-peak hours functioning
No
No
No
Rated heat output, under colder - warmer climate conditions
kW
5 – 4
4 – 4
6 – 6
Space heating - Annual energy consumption, under colder -
warmer climate conditions
kWh
4483 – 1173
3721 – 1394
4621 – 2029
Water heating - Annual energy consumption, under colder -
warmer climate conditions
kWh
1111 – 567
943 – 664
976 – 675
Seasonal space heating energy efficiency, under colder - warm
er climate conditions
%
109 – 156
116 – 150
119 – 155
Water heating energy efficiency, under colder - warmer climate
conditions
%
92.00 – 181.00 109.00 –
154.00
105.00 –
152.00
Sound power level L
WA
outdoors
dB
55
57
61
(1) For gas heat pumps only
(2) If applicable.
(3) Electricity
(4) Fuel
See
For specific precautions on assembly, installation and
maintenance: see the "Safety Instructions" chapter
14.2 Product fiche - Temperature Controls
Tab.87 Product fiche for the Temperature controls
MK2
Class
II
Contribution to space heating energy efficiency
%
2
14 Appendix
134
7654506 - v06 - 19112019