6.0 Error Codes
9
© Baxi Heating UK Ltd 2013
6.1
List of Error Codes
1. When an error occurs the display will show one of two
symbols: or .
In both cases the display will also show symbol and the
numeric value of the error (see the “error table” below).
2. When the spanner is displayed the error cannot be
reset by the user. Please contact ‘
heateam
’ - The Service
Division of Baxi on
0844 241 2502
or e-mail
3. fault errors can be reset by pressing the button
and holding for two seconds.
WARNING:
If an error code different from those
described opposite appears on the display or a certain fault
appears frequently, contact ‘
heateam
’.
R
R
Table Of Error Codes
R
Central Heating NTC Fault
Flue NTC Fault
Central Heating Return NTC Fault
Safety Thermostat Operated (pump fault or air in primary)
Safety Thermostat Operated (over temperature)
Primary System Water Pressure Too High
Primary System Water Pressure Too Low
Circulation Fault (Primary)
Flame Failure (no lock-out)
Flue NTC Operated
Interruption Of Gas Supply or Flame Failure
Flame Failure
Fan or Fan Wiring Fault
False Flame
20
28
40
110
111
117
118
125
128
130
133
151
160
384
R
R
R
R
R
R