3 Description
3.1
Operating principle
3.1.1.
Gas/air setting
The casing fitted to the boiler is also used as an air box. Air is sucked
in by the fan and gas injected into the venturi by the fan intake. The
fan rotation speed is set according to the settings parameters, the
thermal energy requirement and the temperatures measured by the
temperature sensors. The gas and air are mixed in the venturi. The
gas/air ratio ensures that the quantities of gas and air are adjusted to
each other. This provides optimum combustion on the entire output
range. The gas/air mixture is fed into the burner on top of the
exchanger.
3.1.2.
Combustion
The burner heats the heating water circulating in the heat
exchanger. At a return temperature lower than around 55°C, the flue
gases cool down to a temperature lower than the dew point, thus
causing the condensation of the water vapour contained in the flue
gases in the lower section of the heat exchanger. The heat released
during this condensation process (the latent heat or condensing heat)
is also transferred to the heating water. The cooled combustion gases
are evacuated via the combustion gas outlet flue. The condensation
water is evacuated via a condensate trap.
3.1.3.
Heating and domestic hot water production
On combi boilers, an integrated plate exchanger heats the domestic
water. A 3-way valve determines whether the heated water is fed into
the heating system or the plate exchanger. A pick-up sensor signals
that a hot water tap is being opened. This signal is transmitted to the
control panel, which then switches the 3-way valve to the hot water
position and trips the heating pump. The 3-way valve is spring-loaded
but only consumes electricity when it switches to another position.
The heating water reheats the domestic water in the plate
exchanger. In comfort mode, if there is no hot water draw-off, the
boiler handles the periodic reheating of the plate exchanger. Any
limescale particles are kept out of the plate exchanger by a self-
cleaning water filter (self-cleans once every 76 hours).
Baxi MainEco Combi and System 24 - 28 - 35 / 18 -24
3. Description
02092014 - 7621607-02
9
Summary of Contents for MainEco Combi 24
Page 5: ...02092014 7621607 02 3 ...
Page 28: ...10 Appendix Baxi MainEco Combi and System 24 28 35 18 24 26 02092014 7621607 02 ...
Page 29: ...Baxi MainEco Combi and System 24 28 35 18 24 10 Appendix 02092014 7621607 02 27 ...
Page 30: ...10 Appendix Baxi MainEco Combi and System 24 28 35 18 24 28 02092014 7621607 02 ...