Supplied By www.heating spares.co Tel. 0161 620 6677
Genesis
Baxi Heating Ltd.
44 - 45
Changing Components – Page 28
Ensure that both the gas and electrical supplies to the
appliance are isolated.
Remove the outer case and door panel as described under
“Servicing the Appliance”.
Isolate the water circuits and drain as necessary.
There are five drain points:
1. Central heating flow valve.
2. Domestic hot water outlet elbow.
3. Domestic cold water inlet valve.
4. Under three way valve.
5. Under automatic air vent.
Place tube on drain point to-drain water away from
electrics. Turn anticlockwise to open.
NOTE: When reassembling ‘O’ ring joints always place
the ‘O’ ring on the spigot
Where appropriate, after changing a component, re-
commission the appliance.
Pressure Switch
Remove the screw holding the pressure switch to the air box
back panel.
Draw the switch forwards, and noting the position of the
electrical connections and pressure pipes, remove them.
Reassemble. in reverse order. of dismantling, and in
accordance with the label on reverse of door panel.
Fan
Slacken the screw securing the fan and elbow seal.
Remove the screws holding the fan sealing plate to the
hood, and disengage the fan from the seal.
Draw the fan assembly forwards, and remove the electrical
connections. Note the position of the earth wire.
Remove the screws holding the sealing plate to the fan, and
remove the plate.
Fit the plate to the new fan, and reassemble in reverse order
of dismantling.