Solarflo - Solar Thermal Domestic Hot Water System
19
The Collector panel temperature sensor should be
installed in the sensor pocket nearest to the collector
array flow. It should be secured in the pocket by inserting
through the rubber gland provided. All materials used for
installing temperature sensors (sensor element, conducting
compound, cables, sealing and insulating materials) must
be suitably temperature resistant (up to 250°C).
3.0
Installation of collector panel sensor
Fig. 6