Baxi Ecogen 24 User Operating Instructions Manual Download Page 9

6.0 Setting the DHW Times

9

© Baxi Heating UK Ltd 2011

Menu Button

Display Screen

04.   November     2008              08:50
Tuesday

6.1

Programming the Domestic Hot Water Times

The i-THINK Controller enables control of up to three periods a
day, seven days a week. 

There are 3 time programs preinstalled to aid reprogramming:-

Time program 1

is the default with 3 time periods - Mon-Sun,

6-9, 11-12 and 15-22.

Time program 2

has two time switch periods - Mon-Sun, 6-9

and 15-22.

Time program 3

has one time switch period 6-22.

‘Preselection’ regimes are: Mon-Sun (Default) Mon-Fri and 
Sat-Sun or each day individually.

When programming individual days, the opportunity to copy one
day to another is offered (screen 575).

04.   November     2008              08:50
Tuesday

Set time and date

---------------------------------------------------

Information

1. The basic display is shown. 
If the basic display is not
showing, press the MENU
button. 

Press the MENU button.

Holidays  heating  CH1

Time  central heating  CH1

Time hot water

Mon - Sun

Select days

Time  hot water

Turn the Selector Button
clockwise to highlight ‘Time hot
water’.

Press the Selector Button
to select .

Press the Selector Button and
the day / days regime flashes.
Turn Button to the required
day or days Mon-Sun, Mon-
Fri, Sat-Sun,
Mon, Tue, Wed,
Thu, Fri, Sat, Sun
Press Button to 
select.

Mon - Sun

Select days

Time  hot water

Turn the Selector Button one
click clockwise. 

Select default timings?

Mon - Sun

Time  hot water

Set to

Time setting 1

Mon - Sun

Time  hot water

Press the Selector Button and
the time program regime
flashes. Turn Button to the
‘Time setting 1’. Press Button to
select and the screen goes back
to STEP 6.

06:00

Mon - Sun: 1st Time ON

Time  hot water

Turn the Selector Button one
click clockwise. 

STEP 1

STEP 2

STEP 3

STEP 4

STEP 5

STEP 6

STEP 7

STEP 8

Selector Button 

i-THINK Controller

Easy Menu Button

Summary of Contents for Ecogen 24

Page 1: ...erating Instructions Important Warranty Information Please keep these instructions in a safe place If you move house please hand them over to the next occupier Ecogen 24 1 0 Gas Fired Wall Mounted Con...

Page 2: ...e for Operating Quick Reference Guide This appliance contains a pressure vessel filled with Helium to 23 bar Do not strike drop drill or puncture the vessel Do not unbolt any of the covers or flanges...

Page 3: ...Easy Menu Button Commonly required functions are available more quickly via the Easy Menu Button To access press the Easy Menu Button and turn the Selector Button to scroll through confirm your selec...

Page 4: ...tic 7 All interactions with the appliance are through the removable i THINK Controller mounted either on the front of the appliance or on a remote wall cradle 2 2 Important Notes 1 Read and follow the...

Page 5: ...estic hot water are set to 24hr operation see sections 7 1 and 7 4 choose On in both cases 4 Refer to the instructions for the existing programmers for setting the timed periods and the room temperatu...

Page 6: ...tton and the minute number flashes Turn Button to the required minute Press the Selector Button Hours minutes 11 30 Set time and date Day month 05 06 Set time and date Turn the Selector Button clockwi...

Page 7: ...day Set time and date Information The basic display is shown If the basic display is not showing press the MENU button until the basic display is shown Press the MENU button Time hot water Operator se...

Page 8: ...time will flash Turn the Button to the required time Press the Button to select Press the Selector Button and the 3rd Time ON time will flash Turn the Selector Button to the required time Press Butto...

Page 9: ...If the basic display is not showing press the MENU button Press the MENU button Holidays heating CH1 Time central heating CH1 Time hot water Mon Sun Select days Time hot water Turn the Selector Button...

Page 10: ...e Button to the required time Press the Button to select Press the Selector Button and the 3rd Time ON time will flash Turn the Selector Button to the required time Press Button to select STEP 11 STEP...

Page 11: ...ntil the next programmed comfort period when the setpoint will revert to the permanent comfort setpoint see Section 7 8 7 3 Optimum start Instead of the heating starting at the Programmed times the op...

Page 12: ...tary burner to light during DHW demands e Eng bu only may be reselected at any time 7 6 Adjusting the DHW Cylinder Temperature 1 If the DHW Cylinder is fitted with a temperature sensor the cylinder se...

Page 13: ...ctor Button 7 8 Adjusting the Room temperature setpoint 1 The room temperature setpoint may be adjusted temporarily as long as the appliance is not in standby or protection mode 2 From the main screen...

Page 14: ...locked appears b In this state any alterations can be made until returning to the standard screen when the programming lock is activated again c To remove the programme lock permanently whilst tempora...

Page 15: ...months 2 Telephone customer service 8 10 Selecting Diagnostics engine The following information is also available by pressing the menu button and selecting Diagnostics engine by pressing the Selector...

Page 16: ...reset can only be carried out on the i THINK Controller when it is not a Room Sensor 2 To perform a user reset a on the 5 LED Receiver press the reset button at the bottom of the unit after a few seco...

Page 17: ...your boiler 6 Your boiler should have the following minimum clearances for Safety and Maintenance Top 200mm Bottom 200mm Left side 5mm Right Side 60mm Front 5mm In Operation 450mm For Servicing 7 If y...

Page 18: ...AR AR 259 CJC sensor Fault cold junction compensation sensor AR 261 Loss of Engine flame No flame after five ignition tries in Engine UR 262 Loss of Supplementary flame No flame after five ignition t...

Page 19: ...e burner BCU isn t consistent AR 423 BCU Supp bu inconsistent Transmitted state of the supplementary burner BCU isn t consistent AR 424 Rep loss of flame Eng bu Repeated loss of flame engine burner UR...

Page 20: ...ity must be left on and the appliance set in the central heating mode 4 The boiler incorporates an integral pump protection feature which continually monitors the time since the pump last operated To...

Page 21: ...inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation The installer is l...

Page 22: ...14 0 Notes 22 Baxi Heating UK Ltd 2011...

Page 23: ...14 0 Notes 23 Baxi Heating UK Ltd 2011...

Page 24: ...trations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in t...

Reviews: