1. Disconnect the electrode leads, noting their positions.
2. Using a 7mm ring spanner remove the 2 long nuts securing each of the electrodes to the engine burner.
3. Replace the sealing gaskets.
4. When replacing the electrodes ensure that they are offered to the assembly vertically to avoid damaging/snagging the internal ceramic block.
5. Reassemble in reverse order.
page 61
14.4 Fan, Venturi Spool Valve (
)
1. Undo the nuts on top of the gas valves.
2. Remove pipes from the venturis.
3. Remove electrical connections from fan and spool valve motor.
4. Undo the three screws securing the manifold onto the burner door.
5. Undo the nut retaining the 22mm pipe at the centre of the engine air/gas manifold.
6. Remove the three screws holding the spool valve on to the side panel. Lift the assembly out.
7. Examine the burner gasket and replace if necessary.
8. Reassemble in reverse order, ensuring that the injector is in place and the sensing pipe is connected to the venturis.
14.5 Spool Valve Motor (
1. Remove the Fan, Venturi Spool Valve Assembly as in
.
2. Remove the 3 screws holding the motor in place.
3. Reassemble in reverse order ensuring the motor drive shaft engages correctly in the spool motor.
14.6 Venturis/Air Flow Straighteners (
1. Remove the Fan, Venturi Spool Valve Assembly as in
.
2. Remove the 8 manifold screws and the 8 nuts attaching the venturis to the 2 air flow straighteners.
3. Slide the venturis and then the air flow straighteners off the long M5 studs.
4. Clean/replace as necessary. Reassemble in reverse order.
14.7 Fan (
1. Remove the Fan, Venturi Spool Valve Assembly as in
.
2. Remove the 4 M5 screws on the fan flange.
3. Reassemble in reverse order.
14.8 Spool Valve (
)
1. Remove the Spool Valve Motor, Venturi, Air Flow Straighteners and Fan see relevant sections above.
2. Remove the countersunk M5 screw retaining the spool valve bush and carefully withdraw the spool valve from the body.
Do not allow the spool valve to slide out in an uncontrolled manner as this may result in damage to the component.
3. Clean/replace as necessary. Reassemble in reverse order.
Summary of Contents for ECOGEN 24/1.0
Page 69: ...Fig 77 Fig 78 Fig 79 page 69 16 0 Schematic Wiring 16 1 Burner Control Units BCU Connections...
Page 70: ...page 70 16 2 Milligrid 24 way Connector...
Page 71: ...page 71 16 3 14 way Connector...
Page 72: ...page 72 16 4 Engine Circuit...
Page 73: ...page 73 16 5 Power Monitoring 24Vdc Power Supply...
Page 74: ...page 74 16 6 External Connections External Wiring...
Page 85: ...page 87...
Page 86: ...page 88...
Page 87: ...page 89 Section P...
Page 88: ...page 90...
Page 89: ...page 91 Section Q Engine developing less than 950W after 15 minutes running at maximum rate...
Page 91: ...page 93 page 94 page 95 page 96 MICRO CHP SYSTEM COMMISSIONING CHECKLIST...
Page 92: ...page 97...