20. VISUALISATION OF PARAMETERS ON THE DISPLAY (“INFO” FUNCTION)
Press “
i
” for at least 5 seconds to visualise certain boiler information on the display on the front panel of the boiler.
N.B.:
when the “INFO” function is enabled, the message “A00”, alternating with the boiler delivery temperature,
is shown on the display (figure 12):
•
Press buttons
(
+/-
) to display the following information:
A00:
current DHW temperature (°C);
A01:
current external temperature (°C) (with external probe connected);
A02:
current (%) at modulator (100% = 230 mA NATURAL GAS - 100% = 310 mA LPG);
A03:
power range (%) (MAX R);
A04:
heating setpoint temperature (°C);
A05:
current heating delivery temperature (°C);
A06:
DHW temperature setpoint value (°C);
A07:
flame signal % value (0-100%);
A08:
value (l/minx10) of the DHW flow rate;
A09:
last error that occurred in the boiler;
•
This function remains active for 3 minutes. It is possible to interrupt the “INFO” function in advance by holding down
the button ( ) for at least 5 seconds, or turning off the power to the boiler.