7651561.02 (1-03/16)
28
USER Section (en)
352/21*('6+87'2:1$17,)5((=(3527(&7,21
'RQRWGUDLQWKHZKROHV\VWHPDV¿OOLQJXSZLWKZDWHUDJDLQFRXOGFDXVHXQQHFHVVDU\DQGKDUPIXOVFDOHWREXLOGXSLQVLGHWKH
ERLOHUDQGWKHKHDWLQJHOHPHQWV,IWKHERLOHULVQRWXVHGGXULQJZLQWHUDQGLVWKHUHIRUHH[SRVHGWRWKHGDQJHURIIURVWDGGVRPH
VSHFL¿FDQWLIUHH]HWRWKHZDWHULQWKHV\VWHPHJSURS\OHQHJO\FROFRXSOHGZLWKFRUURVLRQDQGVFDOHLQKLELWRUV7KHHOHFWURQLF
ERLOHUPDQDJHPHQWV\VWHPLQFOXGHVD³IURVWSURWHFWLRQ´IXQFWLRQIRUWKHKHDWLQJV\VWHPZKLFKZKHQGHOLYHU\WHPSHUDWXUHIDOOV
EHORZ&OLJKWVWKHEXUQHUXQWLODGHOLYHU\WHPSHUDWXUHRI&LVUHDFKHG
The function is operative if: the boiler is electrically powered, there is gas, system pressure is normal and the boiler is not
blocked.
3. GAS CONVERSION
The boilers can operate both on natural gas (G20) and LPG (G31). All gas conversions must be made by the AUTHORISED
TECHNICAL SERVICE CENTRE.
)$8/76
7KH IDXOWV VKRZQ RQ WKH GLVSOD\ DUH LGHQWL¿HG ZLWK WKH V\PERO
and a number (fault code). For a
FRPSOHWHOLVWRIIDXOWVVHHWKHIROORZLQJWDEOH
If
appears on the display the fault must be RESET by the user.
7R5(6(7WKHERLOHUSUHVVDQGKROGGRZQ
for 2 seconds. If faults are displayed frequently, call the
Authorised Service Centre.
Description of fault
Action
09
Gas valve connection error
Call the Authorised Service Centre.
10
External probe sensor faulty
Call the Authorised Service Centre.
12
+\GUDXOLFGLIIHUHQWLDOSUHVVXUHVZLWFKVZLWFKLQJIDLOXUH
Call the Authorised Service Centre.
13
+\GUDXOLFGLIIHUHQWLDOSUHVVXUHVZLWFKFRQWDFWVVWXFN
Call the Authorised Service Centre.
15
Gas valve control error
Call the Authorised Service Centre.
18
+\GUDXOLFFLUFXLWDXWRPDWLF¿OOLQJLQSURJUHVV
:DLWIRUWKHHQGRIWKH¿OOLQJF\FOH
19
)DXOWLQV\VWHP¿OOLQJSKDVH
3UHVVDQGKROGGRZQ
for at least 2 seconds.
20
17&ÀRZVHQVRUIDXOW\
Call the Authorised Service Centre.
28
NTC fumes sensor faulty
Call the Authorised Service Centre.
40
NTC return sensor faulty
Call the Authorised Service Centre.
50
17&GRPHVWLFKRWZDWHUVHQVRUIDXOW\
RQO\IRUKHDWLQJRQO\PRGHOZLWKVWRUDJHERLOHU
Call the Authorised Service Centre.
53
Fumes outlet obstructed
'LVFRQQHFWWKHERLOHUIURPWKHPDLQVSRZHUVXSSO\
IRUDIHZVHFRQGV
If the fault persists, call the authorised
technical service centre
55
Electronic board not calibrated
Call the Authorised Service Centre.
83…87
&RPPXQLFDWLRQSUREOHPEHWZHHQERLOHUERDUGDQGFRQWURO
XQLW3UREDEOHVKRUWFLUFXLWRQZLULQJ
Call the Authorised Service Centre.
92
Fumes fault during calibration (probable fumes
recirculation)
Call the Authorised Service Centre.
109
Air in boiler circuit
(temporary fault)
Call the Authorised Service Centre.
110
Safety thermostat tripped due to overtemperature (pump
probably blocked or air in heating circuit).
3UHVVDQGKROGGRZQ
for at least 2 seconds.
117
Pressure in hydraulic circuit too high (> 2,7 bar)
Call the Authorised Service Centre.
118
3UHVVXUHLQK\GUDXOLFFLUFXLWWRRORZ
&KHFNWKDWWKHSUHVVXUHLQWKHV\VWHPLVFRUUHFW6HHWKH
FILLING THE SYSTEM section.
125
No circulation safety trip
(control performed via a temperature sensor)
3UHVVDQGKROGGRZQ
for at least 2 seconds.
128
1RÀDPH
3UHVVDQGKROGGRZQ
for at least 2 seconds.
129
/RVVRIÀDPHDWLJQLWLRQ
Call the Authorised Service Centre.
130
Fumes NTC tripped due to overtemperature
3UHVVDQGKROGGRZQ
for at least 2 seconds.
133
Ignition failure (5 attempts)
3UHVVDQGKROGGRZQ
for at least 2 seconds.
134
Gas valve blocked
3UHVVDQGKROGGRZQ
for at least 2 seconds.
135
Internal board error
3UHVVDQGKROGGRZQ
for at least 2 seconds.
Summary of Contents for DUO-TEC MAX+
Page 90: ...7651561 02 1 03 16 90 6 7 2 1...
Page 94: ...7651561 02 1 03 16 94 6 7 2 1 7218789 01 53 5 41 5...
Page 95: ...95 6 7 2 1 7651561 02 1 03 16 53 5 41 5 A 168 5 22...
Page 96: ...7651561 02 1 03 16 96 6 7 2 1 25 mm...
Page 99: ...99 6 7 2 1 7651561 02 1 03 16...
Page 100: ...7651561 02 1 03 16 100 6 7 2 1...
Page 102: ...7651561 02 1 03 16 102...
Page 103: ...103 7651561 02 1 03 16...