Now connect the wiring loom at the firebox end, the eight pin connector is located on
the lower left hand side of the appliance. Take two ‘P’ clips from the loose parts bag,
and use them to secure the loom to the upper left hand side of the firebox. Two fixing
holes can be found in this area of the firebox.
Use the fixing screws provided and now secure the ‘P’ clips and the loom over the top
of the insulation jacket ensuring that approximately 250mm of slack exists between the
eight pin connector and the first ‘P’ clip.
This slack is necessary to allow removal
of the electrical control unit in future
servicing.
Obtain the previously prepared flue tube
and attach to the spigot on the back of
the firebox.
Ensure that the flue pipe is not fitted in
reverse. i.e. The stepped end is the
firebox end.
Now offer the complete assembly as a
unit to the wall.
Take care not to damage the wiring loom
as the flue pipe is inserted through the
wall.
Now it is necessary to secure the firebox
to the wall.
8.1 Securing firebox to wall - cable retention.
1.
Assemble retention cables into firebox.
2.
Insert cables into cable anchor points in upper rear of firebox and then tape together
adjoining edges of the jacket as shown in figure 18.
3.
Offer the firebox up to the wall and feed the retention cable through the installed
eyebolts.
4.
Return the cables through the holes provided at the lower back of the firebox.
5.
Assemble adjusters and tension as in figure 19
.
8.2 Securing firebox to wall using fixing brackets.
1.
Loose assemble the two fixing brackets provided (See figure 20) using the screws
provided.
2.
Offer fire up to wall.
3.
Establish the final location of firebox, and secure fixing brackets accordingly.
4.
Mark off the wall, drill two holes using no.10 drill bit. Insert wall plugs.
5.
Firebox is now ready to secure using wood screws provided.