2.0 Technical Data
1
5
Bermuda Inset 3 TS, BS, FS, KS Super
Bermuda Inset 3 BB, CB, SC, BC Super
The fire is set for Gas Type G20 at 20mbar.
Heat Input
(Gross)
High
Low
kW
6.52
4.1
Btu/h
22,246
13,989
Pilot Assembly
9416
Heat Input (Gross) 210W (715 Btu/h)
Injector
F15
Setting Pressure
Cold
mbar
9.0
in wg
3.6
Thermocouple
6.5 - 10.0 mv
Output
Gas Connection
The gas supply is
provided from the service
cock on the boiler unit
Electrical Supply
230V ~ 50Hz 65W
Supplied from boiler
electrical socket.
Fused 5A in boiler
external supply.
Controls
Automatic control system
with flame failure and
atmospheric sensing
device.
Gas Rate
(after 10 mins)
0.60 m
3
/h (21.0 ft
3
/h)
Installation
Lifting Weight
10.3 kg (22.7 lbs)
Outercase
Height
610mm
Dimensions
Width
593mm
Depth
103mm
(from the wall)
Notice
Discolouration of wall surfaces
Most heating appliances generate warm air convection currents and
transfer heat to any wall surface against which they are situated.
Some soft furnishings (such as blown vinyl wallpapers) may not be
suitable for use where they are subject to temperatures above normal
room levels and the manufacturer's advice should be sought before
using this type of wall covering adjacent to any heating appliance.
The likelihood of wall staining from convected air currents will be
increased in environments where high levels of cigarette smoke or
other contaminants exist.