3.0 Arranging

the Coal

s

~

...

.

.

10

.

Coal H should be plac

e

d l

engthw

ays ac

ro

ss

coals F and C, and against t

he rear s

uppo

rt

.

I

t

s

contoured face should be

t

o

t

h

e front

(Fig

.

10

)

.

11

.

Coal I should be plac

ed lengthway

s acr

os

s

coals G and C

,

and aga

i

n

st the rear su

pp

o

r

t

.

I

ts

contoured face should b

e to the front (Fig

.

11)

.

~

.

.

..

..

.

..

.

I

I

12

.

Take coa

l

J an

d i

nser

t it between the

rearward fac

i

ng project

i

ons

of coal C

.

it

s n

arrow

end forwards (F

i

g

.

12

).

~

.

.

..

13. Place coal K on

t

he

left hand side

of coal D

and against the left hand s

i

d

e cheek

.

Th

e

contoured faces of the co

al should be u

p

p

e

rm

os

t

and facing inwards to th

e other coals (Fig

.

1

3

)

.

14

.

Place coal L on the

right hand side

o

f coal E

and aga

i

nst

t

he rig

ht

ha

nd side cheek. The

contoured fac

e

s of

th

e co

al should be uppermost

and facing

i

nwards to

t

he

other coals (Fig. 14)

.

~

..

.

..

15. Locate the cut-ou

t in the underside

o

f c

o

al M

on the rear support

.

It sho

uld also rest

o

n

co

al I

(Fig

.

15).

16

.

Locate the c

u

t

-

out

i

n

the underside

o

f

co

al N

on the rear support

.

I

t

s

h

o

uld also rest

o

n coal H

(Fig

.

16

)

.

Fi

g

. 14

~

.

~

Coal M

17

.

The upper sur

f

a

c

es o

f coals M and N should

form a

"

V

"

shaped rec

e

ss

.

18. Finally

,

take coal

0

a

nd place it's convex

face forwards across coal

s M and N (Fig

.

17).

19

.

Ensure that the comp

leted coal bed is as

show

n i

n the photog

r

aph

below

.

.

.

.

.

...

.

..

~

F

ig.4x

57132

Fig.5x

Summary of Contents for Baxi Belgravia Deluxe

Page 1: ...uctions safe Should you move house please hand them over to the next occupier Baxi Cavendish Deluxe Baxi Kingston Deluxe Baxi Belgravia Deluxe Live Fuel Effect Inset Gas Fires User s Operating Instructions SAXI HEATING 57132 ...

Page 2: ...keep ahead of changing trends we have made a commitment to develop new ideas using the latest technology with the aim of continuing to make the products that customers want to buy Baxi is also the largest manufacturing partnership in the country Everyone who works at the company has a commitment to quality because as shareholders we know that satisfied customers mean continued We hope you get a sa...

Page 3: ...be carried out by a CORGI Registered Installer or other competent person and be in accordance with the relevant requirements of GASSAFETY Installation and Use REGULATIONS 1994 as amended the BUILDING REGULATIONS issued by the Department of the Environment BUILDING STANDARDS Scotland Consolidation REGULATIONS issued by the Scottish Development Department and the LOCALBUILDING REGULATIONS Where no s...

Page 4: ...e control lever down for twenty seconds 4 Release the control lever It will go to the LOW SUMMER rate position To obtain MEDIUM and HIGH gas rates move the control lever upwards to the appropriate position Moving the control lever to the uppermost position will extinguish the fire 5 The light effect is controlled by a master switch behind the controls access door With the master switch in the ON p...

Page 5: ...ome time Cleaning must only be done using a very soft brush The coals may be retouched with Baxi coal bed stain available direct from Baxi heating or from your local Baxi Spares Stockist Quote Part N 043224 when ordering CAUTION The coals are extremely fragile and must be handled accordingly To avoid soiling ones hands gloves should be worn and any inhalation of the dust should be avoided Keep the...

Page 6: ... rear tabs The convex face of the support must be to the front and the location pegs uppermost Fig 4 5 Place the flat face of coal C on the front support with the two projections to the rear and resting on the rear support Fig 5 6 Coal D should be put to the left of coal C with it s flat face downwards onto the front support and the short projection to the rear Fig 6 7 The flat face of coal E shou...

Page 7: ...coal should be uppermost and facing inwards to the other coals Fig 13 14 Place coal L on the right hand side of coal E and against the right hand side cheek The contoured faces of the coal should be uppermost and facing inwards to the other coals Fig 14 15 Locate the cut out in the underside of coal M on the rear support It should also rest on coal I Fig 15 16 Locate the cut out in the underside o...

Page 8: ... of the installer for the first twelve months after which time if spare parts are required they can be obtained through approved Baxi stockists or local gas region 2 Appliance information may be found on the Data Badge which is situated inside the fire on the lower right hand side It is necessary to remove the fire trim Key Description Manufacturers No Part No B Knob Thermostat 239328 F Coal Rear ...

Page 9: ...iginal user 3 To maximise the benefit from our guarantee we urge you to return the reply paid guarantee registration 4 This does not in any way prejudice your rights at Common Law Such rights between the customer and the installer or supplier from whom the unit was purchased remain intact Any component or part which becomes defective during the guarantee period as a result of faulty workmanship or...

Page 10: ...6 0 Notes 57132 ...

Page 11: ...omprehensive range of products for the domestic heating market Gas Central Heating Boilers Wall Floor and Fireside models If you require information on any of these products please write telephone or fax to the Sales Department 57132 ...

Page 12: ...lines For General Enquiries 44 0 1772 695 555 For Mter Sales Service 44 0 1772 695 505 For Technical Enquiries 44 0 1772 695 504 SAXI Baxi Heating Limited Brownedge Road Bamber Bridge Preston Lancashire PR56SN 57132 ...

Reviews: