9. CONVECTION BOX INSTALLATION
9.1 Method 1 - Front fixing to fireplace surround.
1.
Make sure that the fireplace front surround area is sound enough to take the fibre
plugs and woodscrews. If necessary, make
sound with suitable cement.
2.
Place the convection box centrally in the
fireplace in the position in which it is to be
permanently installed. If a concealed
connection is being used, insert the
convection box into the fireplace feeding the
supply pipe through the pierced hole in the
rear grommet.
3.
Mark the fireplace front surround through
the four fixing holes in the side flanges of the
convection box (See figure 16).
4.
Remove the convection box. Drill four
holes in the fireplace front surround at the
marked positions using a
suitably sized masonry drill for
the wall plugs supplied.
5.
Insert a fibre plug into each
hole.
6.
Place the convection box
back in position in the fireplace.
7.
Fit a woodscrew through
each hole in the convection box
flanges and tighten to seal the
box to the fireplace surround.
9.2 Method 2 - Cable
retention and floor fixing.
1.
Make sure that the relevant
areas at the fireplace back or
floor are sound enough to take
the eyebolts and screws. If
these areas have deteriorated
due to prolonged use they
should be made sound with
suitable cement.
2.
Drill four holes in the rear
wall of the fireplace for the
eyebolt plugs. The holes should
Page 22
©
Baxi Heating U.K. Limited 2010.
Figure 17. Eyebolt positions
Figure 16. Front fixing
INSTALLER GUIDE