GAS CONSUMPTION

Model 740

Has a maximum natural gas input of 6.85kW (Gross)
Has a maximum natural gas output of 4.0kW 

Has a minimum natural gas input of 2.7kW (Gross)
Has a minimum natural gas output of 1.34kW 

Model 740 when converted using kit number 

0595211

 

Has a maximum propane gas input of 6.7kW (Gross)
Has a maximum propane gas output of 3.9kW 

Has a minimum propane gas input of 4.3kW (Gross)
Has a minimum propane gas output of 2.29kW 

OPERATING YOUR FIRE

The Oxysafe flame sensing and flue blockage safety system.

For your safety, this appliance is fitted with a flue blockage safety device which will
shut down the appliance in the event of abnormal flue conditions. 

This device is NOT a

substitute for an independently mounted Carbon Monoxide detector. 

The device will also automatically shut off the gas supply to the fire if the pilot flame
goes out due to lack of oxygen or for any other reason.

If this device starts to repeatedly shut off the gas, get expert advice.

This device incorporates a probe which senses that the heat from the pilot flame is
correct.  If this probe is cool, the device will prevent any gas flow unless the control
knob is held in at the ignition position. 
If, for any reason, the flames go out when the fire is hot or if the fire is turned off when
hot, always 

wait at least three minutes before attempting to relight

.

Page 6

OWNER GUIDE

PLEASE NOTE

When operating your fire for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after a few hours use.

Summary of Contents for 740FS

Page 1: ...NVERSION KIT NO 0595211 THIS APPLIANCE IS FOR USE WITH PROPANE GAS G31 THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE Baxi Heating U K Ltd Model 740FS Heat Engine GC No 32 032 55 INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING THE CONTROL For technical advice firstly contact your retailer If further advice is required then call 0161703 8157 f...

Page 2: ...cturer is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation The manufacturer is a CORGI registered company This gas fire must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should not be fitted directly on to a carpet Baxi Fires Division Erdington Birmingha...

Page 3: ...ner 9 CERAMIC FUEL BED REFITTING 9 MAINTENANCE 9 Battery replacement 9 Regular maintenance 9 Servicing 10 This gas fire is designed to meet the most stringent quality performance and safety requirements to provide you with many years trouble free service This guide aims to improve your understanding and appreciation of your gas fire by providing simple and informative instructions to ensure that y...

Page 4: ...clearance of 760 mm from the top of the base of the convetcor box to the underside of any shelf whether it is made from combustible or non combustible materials For a shelf made from wood or other combustible materials deeper than 150mm add 12 5mm to the clearance for every 25mm of additional shelf depth See graph 1 Please bear this in mind if ever you add a shelf Page 4 OWNER GUIDE IF YOU SMELL G...

Page 5: ...re considering redecorating Do provide a minimum side clearance as detailed below The minimum mandatory side clearance to combustible surfaces projecting beyond the front of the appliance is 100mm For access purposes a 10mm clearance to non combustible surfaces is recommended on the left side of the appliance on the right side the recommended clearance is 50mm for access to the slider control Plea...

Page 6: ...bon Monoxide detector The device will also automatically shut off the gas supply to the fire if the pilot flame goes out due to lack of oxygen or for any other reason If this device starts to repeatedly shut off the gas get expert advice This device incorporates a probe which senses that the heat from the pilot flame is correct If this probe is cool the device will prevent any gas flow unless the ...

Page 7: ...hes the high heat position you will feel a check to its movement Do not slide the button above the high heat position unless you want to turn the fire off See note i below Note i If the flames go out while setting the control repeat the full lighting procedure If the flames repeatedly go out have the fire serviced ii Please note When first turned on the flames will appear predominantly blue The fu...

Page 8: ...ith a slightly damp cloth and then dry Do not use abrasive cleaners as these will scratch the fire surface Ceramic fuel effect pieces and burner compartment walls This product uses fuel effect pieces and burner compartment walls containing Refractory Ceramic Fibres RCF which are man made vitreous silicate fibres Excessive exposure to this material may cause irritation to eyes skin and respiratory ...

Page 9: ...he installer and owner guide for the ceramic fuel effect is followed correctly If replacing the ceramic fuel effect where a new guide is supplied follow the installer and owner guide supplied with the replacement fuel effect Keep the replacement installer and owner guide with this owner guide for future reference MAINTENANCE Battery replacement This appliance requires one 9V PP3 Ever Ready Silver ...

Page 10: ...try to have the following information available before you contact us Type of fire Model Name Serial Number You will also be asked for the fault problem or request plus your Post Code If you wish to replace any of the ceramic fuel effect pieces spare parts are available nationwide via the interpart stockist network For your local stockist consult Yellow pages under Central Heating When fitting rep...

Reviews: