SAFETY
Do
have the fire installed by a competent person. In the United Kingdom, installation
must be in accordance with the latest edition of the Gas Safety (installation & use)
Regulations. In the Republic of Ireland, installation must be in accordance with all
national and local regulations in force.
Do
have the fire installed in accordance with the installer guide.
Do
provide a minimum clearance of 700mm from the firebox base to any
shelf made of wood or other combustible material where the shelf is not more than
150mm deep. For a shelf deeper than 150mm, add 12.5mm to the clearance for every
25mm of additional shelf depth (See graph1).
Do
Make sure that any combustible wall finish or cladding is removed from the area
within the fascia of the fire.
Page 4
OWNER GUIDE
IF YOU SMELL GAS
DON’T SMOKE.
EXTINGUISH ALL NAKED FLAMES.
DON’T TURN ELECTRICAL SWITCHES ON OR OFF.
TURN OFF THE GAS SUPPLY AT THE METER.
OPEN DOORS AND WINDOWS TO GET RID OF THE GAS.
IMMEDIATELY CALL THE GAS EMERGENCY SERVICE – SEE YOUR LOCAL TELEPHONE
DIRECTORY.
Graph 1. Combustible shelf clearances