© Baxi Heating U.K. Limited 2006.

All rights reserved. No part of this publication may be reproduced in any material form

(including photocopying), stored in any medium by electronic means (including in any

retrieval system or database) or transmitted, in any form or by any means, whether

electronic, mechanical, recording or otherwise, without the prior written permission of

the copyright owner.

Applications for the copyright owner's permission to reproduce any part of this

publication should be made, giving details of the proposed use, to the following address:

The Company Secretary, Baxi Heating UK Limited, Pentagon House, Sir Frank Whittle

Road, Derby, DE21 4XA.

Warning: Any person who does any unauthorised act in relation to a copyright work

may be liable to criminal prosecution and civil claims for damages.

Baxi Fires Division, Erdington, Birmingham B24 9QP

www.firesandstoves.co.uk

Because our policy is one of constant development and improvement, details may vary slightly from those

given in this publication

Page 2

OWNER GUIDE

© 

Baxi Heating U.K. Limited 2006.

THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20).

WHEN CONVERTED USING CONVERSION KIT NO. 0595221 THIS

APPLIANCE IS FOR USE WITH PROPANE GAS (G31).

THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED

KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE).

Summary of Contents for 750

Page 1: ... appliance to be operated and maintained satisfactorily However if further information is required our Baxi Fires Division Technical Helpline will be pleased to help Telephone 08706 061 065 National call rates apply in the United Kingdom In the Republic of Ireland Telephone 0044 8706 061 065 This guide is intended to help you care for your Baxi Fires Division gas fire Please read thoroughly before...

Page 2: ...ess The Company Secretary Baxi Heating UK Limited Pentagon House Sir Frank Whittle Road Derby DE21 4XA Warning Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Baxi Fires Division Erdington Birmingham B24 9QP www firesandstoves co uk Because our policy is one of constant development and improvement details m...

Page 3: ...y the British Standards Institute The Highest Standards Baxi Fires Division is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Baxi Fires Division is a CORGI registered company All our gas fires must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should n...

Page 4: ...eramic fuel effect and rear wall 9 Burner 10 CERAMIC FUEL EFFECT REFITTING 10 MAINTENANCE 10 Regular maintenance 10 Servicing 11 USEFUL TELEPHONE NUMBERS 11 This gas fire is designed to meet the most stringent quality performance and safety requirements to provide you with many years trouble free service This guide aims to improve your understanding and appreciation of your gas fire by providing s...

Page 5: ...od or other combustible material where the shelf is not more than 150mm deep For a shelf deeper than 150mm add 12 5mm to the clearance for every 25mm of additional shelf depth See graph1 Do always use a fireguard complying with BS 8423 for the protection of young children the elderly the infirm or pet animals Do wait three minutes before attempting to relight if the fire is switched off or the Pag...

Page 6: ...you are altering the room Don t hang clothing towels or any other fabrics over the fire Don t put more ceramic fuel effect pieces on the fire than the number given in this guide or use any ceramic fuel effect pieces other than those authorised for this fire Incorrect combustion could result Don t put paper or other materials onto your fire Don t use the fire with damaged base ceramics Don t place ...

Page 7: ... The device will also automatically shut off the gas supply to the fire if the pilot flame goes out due to lack of oxygen or for any other reason If this device starts to repeatedly shut off the gas get expert advice This device incorporates a probe which senses that the heat from the pilot flame is correct If this probe is cool the device will prevent any gas flow unless the control knob is kept ...

Page 8: ...es and then repeat the ignition procedure Lighting the main burner Once the pilot light is established the main burner can be lit by depressing and turning the control knob anticlockwise to the High position Selecting the heat setting In order to change from one setting to another depress the control knob slightly and turn the knob to the required position Any setting from Low to High may be selec...

Page 9: ...urther use Metal parts Clean the metal parts with a slightly damp lint free non abrasive cloth and then dry Do not use abrasive cleaners as these will scratch the fire surface Fascia Clean the metal parts with a slightly damp cloth and then dry If this does not work apply a very small amount of baby oil to a lint free non abrasive cloth and wipe over the surface Use a clean cloth to wipe off the o...

Page 10: ...llowed correctly If replacing the ceramic fuel effect where a new guide is supplied follow the installer and owner guide supplied with the replacement fuel effect Keep the replacement installer and owner guide with this owner guide for future reference MAINTENANCE Regular maintenance In order to achieve and maintain high levels of personal safety and performance efficiency it is essential that the...

Page 11: ...e available nationwide via the interpart stockist network For your local stockist consult Yellow pages under Central Heating When fitting replacement parts it is important that only approved parts are used for maximum safety USEFUL TELEPHONE NUMBERS General advice about gas and your gas fire BAXI FIRES DIVISION TECHNICAL HELPLINE 08706 061 065 To report faults or arrange for your fire to be servic...